THE USE OF INDIRECT CALORIMETRY IN CRITICALLY ILL PATIENTS—THE RELATIONSHIP OF MEASURED ENERGY EXPENDITURE TO INJURY SEVERITY SCORE, SEPTIC SEVERITY SCORE, AND APACHE II SCORE
The DOI matches its Crossref record.
Abstract
The nutritional needs of critically ill septic patients or patients with multiple injuries are often difficult to estimate. Indirect calorimetry can simply and accurately determine individual caloric and nutritional needs, especially in cases of critically ill patients with complicated injuries. This prospective study compared the measured energy expenditures of 30 patients using indirect calorimetry with their predicted basal energy expenditure according to the Harris-Benedict equation, or their calculated energy expenditure derived from basal energy expenditure times, an activity factor, and a stress factor. These numbers were then used to evaluate the relationship between measured energy expenditure, measured energy expenditure per kilogram, and four specific scoring systems--the Septic Severity Score (SSS), the Injury Severity Score (ISS), the Trauma Score (TS), and APACHE II. The results showed the severity of sepsis or trauma correlated with the measured energy expenditure per kilogram of body weight. Among the 15 septic patients, in whom the measured energy expenditure per kilogram was 42.2 +/- 2.6 kcal/kg, the SSS provided a better predictor of energy needs and closer correlation with measured energy expenditure per kilogram (r = 0.69, Y = 1.41 + 0.72 X). Their stress factors could be modified as "0.97 + 0.0125 x SSS" to get a more accurate Harris-Benedict calculation. For the 15 patients with multiple injuries in whom the measured energy expenditure per kilogram was 34.9 +/- 1.6 kcal/kg, the ISS offered the best correlation with measured energy expenditure per kilogram (r = 0.84, Y = -31.47 +/- 1.73 X). Their stress factors could be modified as "1.04 + 0.0077 x ISS" to get a more accurate Harris-Benedict calculation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Uehara, M., Plank, L. D., & Hill, G. L. (1999) · Critical Care Medicine · doi:10.1097/00003246-199907000-00015 · Cited by 203
Accurate Determination of Energy Needs in Hospitalized Patients
Boullata, J., Williams, J., Cottrell, F., Hudson, L., & Compher, C. (2007) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2006.12.014 · Cited by 201
Energy Expenditure in Hospitalized Patients: Implications for Nutritional Support
Miles, J. M. (2006) · Mayo Clinic Proceedings · doi:10.4065/81.6.809 · Cited by 76
Metadata
- Authors
- Hwang, T.-L., Huang, S.-L., & Chen, M.-F.
- Venue
- The Journal of Trauma: Injury, Infection, and Critical Care
- Published
- 1993-02
- Volume
- 34
- Issue
- 2
- Pages
- 247-251
- ISSN
- 0022-5282 (ISSN-L)
- OpenAlex
- W2007909259
- Cited by
- 68
- References
- 0
- FWCI
- 2.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: THE USE OF INDIRECT CALORIMETRY IN CRITICALLY ILL PATIENTS—THE RELATIONSHIP OF MEASURED ENERGY EXPENDITURE TO INJURY SEVERITY SCORE, SEPTIC SEVERITY SCORE, AND APACHE II SCORE. https://app.cochat.ai/papers/10.1097/00005373-199302000-00013
- The paper
- Hwang, T.-L., Huang, S.-L., & Chen, M.-F. (1993). THE USE OF INDIRECT CALORIMETRY IN CRITICALLY ILL PATIENTS—THE RELATIONSHIP OF MEASURED ENERGY EXPENDITURE TO INJURY SEVERITY SCORE, SEPTIC SEVERITY SCORE, AND APACHE II SCORE. The Journal of Trauma: Injury, Infection, and Critical Care. https://doi.org/10.1097/00005373-199302000-00013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.