Student or educator? Sign up with your school email and get 6 months of Pro free.

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Microvascular Response to Compartment Syndrome-Like External Pressure Elevation: An In Vivo Fluorescence Microscopic Study in the Hamster Striated Muscle

Vollmar, Brigitte, Westermann, Simone, Menger, Michael D.·1999·The Journal of Trauma: Injury, Infection, and Critical Care

Abstract

OBJECTIVE: To quantitatively assess the nature and the magnitude of the microvascular response of striated muscle tissue upon elevation of external pressure, as in compartment syndrome. METHODS: Using the skinfold chamber model in Syrian golden hamsters and intravital fluorescence microscopy, we studied the individual response of the different segments of the microcirculation, i.e., the arterioles, capillaries, and postcapillary venules, in terms of vasomotor control (change of vessel diameter) and cessation of blood flow upon defined changes in external tissue pressure. RESULTS: The unique findings of our study are that (1) arteriolar flow ceased at mean external pressures of 25.6+/-2.4, 28.3+/-2.8, 34.5+/-4.6, and 44.4+/-6.8 mm Hg in vessels with diameters of less than 20, 20 to 40, 40 to 60, and greater than 60 microm, respectively, without signs of spasm or collapse even at a pressure maximum of 70 mm Hg, whereas (2) in venules the increase of external pressure was associated with a diameter reduction ranging from 5 to 25% with cessation of blood flow at mean external pressures between 27 and 33 mm Hg. Blood flow ceased in 50% of the muscle capillaries already at an external pressure of 12 mm Hg. Thus, at distinct external pressure levels venous and capillary blood flow ceased, but arterioles were still capable of carrying flow, which was directed along arteriolo-arteriolar "thoroughfare" channels. To restart blood flow, external pressure had to be decreased by 9, 11, 15, and 17 mm Hg in arterioles with diameters of less than 20, 20 to 40, 40 to 60, and greater than 60 microm, and by approximately 9 mm Hg in venules regardless of vessel diameter. Capillary blood flow was found to be restored at a mean reduction of external tissue pressure of approximately 4 mm Hg. CONCLUSION: Our study disproves the critical closing theory but complies-in particular because of the supposed constriction-induced increase of venular resistance-with the hypothesis of reduced arteriovenous pressure gradients as the cause of flow cessation in compartment syndrome. The necessity of a substantially increased perfusion pressure gradient to restart blood flow in arterioles, capillaries, and venules confirms the existence of yield stress in these microvessels. The high susceptibility of capillaries to elevated external pressure indicates the necessity of early fasciotomy to restore impaired nutritive circulation in cases of compartment syndrome.

Overview

Integrity signals

Registry

Crossref · 10.1097/00005373-199901000-00015

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 12 references

Research works printed but not linked: 8

  1. Gardner, 1970, Clin Orthop, 72, 261
  2. Ashton, 1962, Clin Sci, 22, 79
  3. Matsen, 1980, Clin Orthop, 150, 187
  4. Oestern, 1991, Unfallchirurg, 94, 210
  5. Menger, 1992, 263, H1892
  6. Burrows, 1981, Am J Physiol, 237, H829
  7. Slaaf, 1987, Int J Microcirc Clin Exp, 6, 215
  8. Sherman, 1980, Am J Physiol, 238, H533

Cited by

See all 69

Metadata

Authors
Vollmar, B., Westermann, S., & Menger, M. D.
Affiliations
Saarland University (DE)
Venue
The Journal of Trauma: Injury, Infection, and Critical Care
Published
1999-01
Volume
46
Issue
1
Pages
91-96
ISSN
1079-6061
OpenAlex
W1999074604
Cited by
68
References
12
Citations by year
2026: 1 · 2025: 1 · 2024: 2 · 2023: 1 · 2022: 5 · 2021: 1 · 2020: 1 · 2019: 4 · 2018: 1 · 2017: 2 · 2016: 3 · 2015: 4 · 2014: 4 · 2013: 2 · 2012: 3
FWCI
1.40
Type
journal article
Language
en
Open access
closed
Locations
PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Muscle and Compartmental Disorders
  • Health Sciences › Medicine › Hematology › Blood properties and coagulation
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
Keywords
compartment syndrome, microvascular response, striated muscle, capillary blood flow, postcapillary venules, vessel diameter, critical closing pressure, perfusion pressure, hamster, intravital fluorescence microscopy, vasomotor control
MeSH terms
Animals, Blood Pressure, Compartment Syndromes, Decompression, Cricetinae, Mesocricetus, Microcirculation, Microscopy, Fluorescence, Pressure, Muscle, Skeletal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microvascular Response to Compartment Syndrome-Like External Pressure Elevation: An In Vivo Fluorescence Microscopic Study in the Hamster Striated Muscle. https://app.cochat.ai/papers/10.1097/00005373-199901000-00015
The paper
Vollmar, B., Westermann, S., & Menger, M. D. (1999). Microvascular Response to Compartment Syndrome-Like External Pressure Elevation: An In Vivo Fluorescence Microscopic Study in the Hamster Striated Muscle. The Journal of Trauma: Injury, Infection, and Critical Care. https://doi.org/10.1097/00005373-199901000-00015

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.