The DOI matches its Crossref record.
Development and Evaluation of an Improved Cochlear Implant Electrode Design for Electric Acoustic Stimulation
Abstract
Objective: The objective of this study was to assess the intracochlear position and the extent of trauma to cochlear structures using a new prototype electrode carrier (Flex EAS). Special emphasis was placed on the practicality for combined electric and acoustic stimulation of the auditory system. Study Design: Human temporal bones were evaluated histologically after insertion of the electrodes, and insertion forces were measured in an acrylic model of the scala tympani. Methods: 1) Insertion forces with the regular C40+ array and the new electrode prototype were measured in an acrylic model of the scala tympani. 2) Ten human temporal bones were implanted using the same surgical procedure as in vivo. All bones underwent fixation methylmethacrylate embedding to allow cutting of the undecalcified bone with the electrode in situ. In addition, radiography of the implanted devices was performed and correlated to histologic results. Electrode positions and trauma to cochlear structures were then evaluated histologically. Results: All insertions of the new electrode array were performed in the scala tympani of the cochlea. All insertions were atraumatic and covered one cochlear turn. The only effect on cochlear structures that could be observed was a slight lifting of the basilar membrane in the middle turn limited to the tip of the electrode. In three bones, basal trauma, which resulted from the cochleostomy itself, could be observed as well. All neural structures remained intact. Conclusions: The new electrode prototype provides very good mechanical properties for safe and atraumatic implantation. All criteria for the use in hearing‐preservation cochlear implantation for electric and acoustic stimulation were fulfilled. Surgical measures to prevent basal trauma appear to be very important.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The cochlear implant: historical aspects and future prospects
Eshraghi, A. A., Nazarian, R., Telischi, F. F., Rajguru, S. M., Truy, E., & Gupta, C. (2012) · The Anatomical Record · doi:10.1002/ar.22580 · Cited by 285
Hearing preservation in cochlear implantation for electric acoustic stimulation
Gstoettner, W., Kiefer, J., Baumgartner, W.-D., Pok, S., Peters, S., & Adunka, O. (2004) · Acta Oto-Laryngologica · doi:10.1080/00016480410016432 · Cited by 277
Self-citationMED-EL Cochlear Implants: State of the Art and a Glimpse Into the Future
Hochmair, I., Nopp, P., Jolly, C., Schmidt, M., Schößer, H., Garnham, C., & Anderson, I. (2006) · Trends in Amplification · doi:10.1177/1084713806296720 · Cited by 254
Metadata
- Authors
- Adunka, O., Kiefer, J., Unkelbach, M. H., Lehnert, T., & Gstoettner, W.
- Venue
- The Laryngoscope
- Publisher
- Wiley
- Published
- 2004-07
- Volume
- 114
- Issue
- 7
- Pages
- 1237-1241
- ISSN
- 0023-852X (ISSN-L)
- 1531-4995
- OpenAlex
- W1976915065
- Cited by
- 184
- References
- 0
- FWCI
- 4.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development and Evaluation of an Improved Cochlear Implant Electrode Design for Electric Acoustic Stimulation. https://app.cochat.ai/papers/10.1097/00005537-200407000-00018
- The paper
- Adunka, O., Kiefer, J., Unkelbach, M. H., Lehnert, T., & Gstoettner, W. (2004). Development and Evaluation of an Improved Cochlear Implant Electrode Design for Electric Acoustic Stimulation. The Laryngoscope. https://doi.org/10.1097/00005537-200407000-00018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.