CoChat

Heart rate reserve is equivalent to %VO2Reserve, not to %VO2max

SWAIN, DAVID P., LEUTHOLTZ, BRIAN C. · 1997 · Medicine & Science in Sports & Exercise

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Percentage of heart rate reserve (%HRR) is widely considered to be equivalent to % of maximal oxygen consumption (%VO2max) for exercise prescription purposes. However, this relationship has not been established in the literature, and a theoretically stronger case can be made for an equivalency between %HRR and %VO2 Reserve (%VO2R) (i.e., the difference between resting and maximal VO2). The current study hypothesized that %HRR is equivalent to %VO2R, not %VO2max, and that the discrepancy between %HRR and %VO2max would be inversely proportional to fitness level. Sixty-three adults performed incremental maximal exercise tests on an electrically braked cycle ergometer. HR and VO2 at rest, at the end of each stage of exercise, and at maximum were used to perform linear regressions on %HRR versus %VO2max, and %HRR versus %VO2R for each subject. For %HRR versus %VO2max, the mean intercept and slope were -11.6 +/- 1.0 and 1.12 +/- 0.01, respectively, which were significantly different (P < 0.001) from 0 and 1, respectively. For %HRR versus %VO2R, the mean intercept and slope were -0.1 +/- 0.6 and 1.00 +/- 0.01, respectively, which were not distinguishable from the line of identity. There was a significant (P < 0.01) inverse relationship between fitness level (VO2max) and the discrepancy between %HRR and %VO2max. In conclusion, %HRR should not be considered equivalent to %VO2max. Rather, %HRR is equivalent to %VO2R, and this relationship should be used in exercise prescription.

Overview

Integrity signals

Registry

Crossref · 10.1097/00005768-199703000-00018

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 5 references

Research works printed but not linked: 5

  1. Davis, 1975, Med Sci Sports, 7, 295
  2. Karvonen, 1957, Ann Med Exp Biol Fenn, 35, 307
  3. Londeree, 1982, Res Q, 53, 297
  4. Pollock, 1980, Comp Ther, 6, 12
  5. Swain, 1994, Med Sci Sports Exerc, 26, 112

Cited by

See all 287

Metadata

Authors
SWAIN, D. P., & LEUTHOLTZ, B. C.
Affiliations
Old Dominion University (US)
Venue
Medicine & Science in Sports & Exercise
Published
1997-03
Volume
29
Issue
3
Pages
410-414
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2057549357
Cited by
287
References
5
Citations by year
2026: 4 · 2025: 15 · 2024: 11 · 2023: 10 · 2022: 14 · 2021: 9 · 2020: 10 · 2019: 19 · 2018: 7 · 2017: 13 · 2016: 10 · 2015: 13 · 2014: 14 · 2013: 15 · 2012: 15
FWCI
7.31
Type
journal article
Language
en
Open access
closed
Locations
  • Medicine & Science in Sports & Exercise (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
Keywords
heart rate reserve, oxygen reserve, VO2max, exercise prescription, cardiorespiratory fitness, heart rate, incremental exercise test, exercise intensity
MeSH terms
Adult, Carbon Dioxide, Exercise Test, Exercise Therapy, Physical Exertion, Female, Heart Rate, Humans, Male, Oxygen Consumption, Physical Fitness, Pulmonary Gas Exchange, Rest, Linear Models, Exercise Tolerance

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Heart rate reserve is equivalent to %VO2Reserve, not to %VO2max. https://app.cochat.ai/papers/10.1097/00005768-199703000-00018
The paper
SWAIN, D. P., & LEUTHOLTZ, B. C. (1997). Heart rate reserve is equivalent to %VO2Reserve, not to %VO2max. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-199703000-00018

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.