The reproducibility of the Bruce protocol exercise test for the determination of aerobic capacity in older women
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The reproducibility of the Bruce exercise test protocol for the determination of maximal aerobic activity was evaluated in sedentary older women. Seventeen women between the ages of 51 and 68 yr performed five maximal graded exercise tests to volitional fatigue on a treadmill. VO2max (mL.kg-1.min-1) values averaged 27.5 +/- 1.1; 28.3 +/- 1.3; 28.4 +/- 1.3; 29.6 +/- 1.5; and 28.2 +/- 1.4 for trials 1-5, respectively, and were not significantly different. Criteria for a plateau in VO2 at the point of exhaustion were met in 21 out of 85 tests (25%). The mean coefficient of variation VO2max for the subjects for the 5 tests was 6.5% (range, 2.0-14%). Pearson's correlation coefficients for the study variables were significant, indicating good agreement between repeated tests (r2: between 0.70 to 0.89). Although there were no significant differences among the mean VO2max values in the 5 trials, 11 subjects had a 1.0 ml.kg-1.min-1 or greater increase in the VO2max from test 1 to test 2, and only 6 subjects had no change or a decrease in VO2max. The mean difference between T2 and T3 was lower (T1 vs T2: 0.8 mL.kg-1.min-1, T2 vs T3: 0.1 mL.kg-1.min-1) indicating slightly better agreement between the second and third set. Estimates of the between and within subject variance revealed a low within subject variance (4.2 (mL.kg-1.min-1)2) compared to the between subject variance (22.1 (mL.kg-1.min-1)2). This study demonstrates that a commonly used exercise testing protocol generates highly reproducible measurements of VO2max in women between 51 and 68 yr. The mean differences between tests and the high level of agreement between repeated tests suggests that a single measurement of VO2max can be performed to assess functional aerobic capacity in this population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Criteria for maximal oxygen uptake: review and commentary
HOWLEY, E. T., BASSETT, D. R., & WELCH, H. G. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199509000-00009 · Cited by 1,656
A comparative analysis of four protocols for maximal treadmill stress testing
Pollock, M. L., Bohannon, R. L., Cooper, K. H., Ayres, J. J., Ward, A., White, S. R., & Linnerud, A. C. (1976) · American Heart Journal · doi:10.1016/s0002-8703(76)80401-2 · Cited by 536
Bortz, W. M. (1982) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1982.03330100041028 · Cited by 192
Biological variability in maximum aerobic power.
KATCH, V. L., SADY, S. S., & FREEDSON, P. (1982) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198201000-00004 · Cited by 187
Cited by
Logical limitations to the “catastrophe” models of fatigue during exercise in humans
Noakes, T. D., & St Clair Gibson, A. (2004) · British Journal of Sports Medicine · doi:10.1136/bjsm.2003.009761 · Cited by 256
Exercise starts and ends in the brain
Kayser, B. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0902-7 · Cited by 243
“The above findings on sedentary subjects are corroborated by the fact that untrained subjects often do not show the so-called plateau phenomenon for V _O2 at the end of an incremental exercise test, the finding of the plateau being proposed as proof of attaining ‘‘true’’ V _O2max ( Fielding et al. 1997 ).”
BackgroundFeasibility of Exercise During Treatment for Multiple Myeloma
Coleman, E. A., Coon, S., Hall-Barrow, J., Richards, K., Gaylor, D., & Stewart, B. (2003) · Cancer Nursing · doi:10.1097/00002820-200310000-00012 · Cited by 219
Tworoger, S. S., Yasui, Y., Vitiello, M. V., Schwartz, R. S., Ulrich, C. M., Aiello, E. J., Irwin, M. L., Bowen, D., Potter, J. D., & McTiernan, A. (2003) · Sleep · doi:10.1093/sleep/26.7.830 · Cited by 168
Statement on Exercise Testing in Cystic Fibrosis
Hebestreit, H., Arets, H. G. M., Aurora, P., Boas, S., Cerny, F., Hulzebos, E. H. J., Karila, C., Lands, L. C., Lowman, J. D., Swisher, A., et al. (2015) · Respiration · doi:10.1159/000439057 · Cited by 165
Metadata
- Authors
- FIELDING, R. A., FRONTERA, W. R., HUGHES, V. A., FISHER, E. C., & EVANS, W. J.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1997-08
- Volume
- 29
- Issue
- 8
- Pages
- 1109-1113
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2012817441
- Cited by
- 53
- References
- 4
- FWCI
- 0.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The reproducibility of the Bruce protocol exercise test for the determination of aerobic capacity in older women. https://app.cochat.ai/papers/10.1097/00005768-199708000-00018
- The paper
- FIELDING, R. A., FRONTERA, W. R., HUGHES, V. A., FISHER, E. C., & EVANS, W. J. (1997). The reproducibility of the Bruce protocol exercise test for the determination of aerobic capacity in older women. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-199708000-00018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.