The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
A comparative evaluation of three accelerometry-based physical activity monitors
Abstract
PURPOSE: Accelerometry-based activity monitors offer promise for the assessment of free-living physical activity. They provide an objective record of frequency, intensity, and duration of physical activity with minimal burden on participants. The purpose of this study was to evaluate the absolute and relative validity of three contemporary activity monitors (Computer Science and Applications, Inc. [CSA], Tritrac, and Biotrainer) under both laboratory and field conditions. METHODS: Fifty-two participants completed two 30-min choreographed routines designed to simulate a variety of lifestyle physical activities. Three different treadmill paces were completed in both routines to evaluate reliability and validity under laboratory conditions. Six different lifestyle activities were also examined to evaluate the validity of the monitors under field conditions. During each routine, the activity levels of participants were monitored with the three activity monitors as well as by indirect calorimetry systems. RESULTS: The correlations between the monitors and measured VO2 were higher for treadmill activity (mean r = 0.86) compared with lifestyle activity (mean r = 0.55). Correlations among the different monitors were high for both treadmill (r = 0.86) and lifestyle activities (r = 0.70), suggesting that the monitors provide similar information under both conditions. Under laboratory conditions, the CSA yielded accurate predictions of energy expenditure (EE), whereas the Tritrac and Biotrainer tended to overestimate the EE (101-136% of measured value). The Tritrac, however, was found to have less error in individual estimates of EE. Under field conditions, all of the monitors underestimated EE (range: 42-67% of measured value). CONCLUSION: The observed differences among the monitors were attributed primarily to differences in the accuracy of the calibration equations rather than to the monitors themselves. Further research is needed to better understand how to use these devices for field-based assessments of physical activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Compendium of Physical Activities: Classification of energy costs of human physical activities
AINSWORTH, B. E., HASKELL, W. L., LEON, A. S., JACOBS, D. R., MONTOYE, H. J., SALLIS, J. F., & PAFFENBARGER, R. S. (1993) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199301000-00011 · Cited by 4,102
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Cited by
Compendium of physical activities: an update of activity codes and MET intensities
AINSWORTH, B. E., HASKELL, W. L., WHITT, M. C., IRWIN, M. L., SWARTZ, A. M., STRATH, S. J., O???BRIEN, W. L., BASSETT, D. R., SCHMITZ, K. H., EMPLAINCOURT, P. O., et al. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00009 · Cited by 8,497
Conducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
The Effect of Social Desirability and Social Approval on Self-Reports of Physical Activity
Adams, S. A. (2005) · American Journal of Epidemiology · doi:10.1093/aje/kwi054 · Cited by 1,160
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Metadata
- Authors
- WELK, G. J., BLAIR, S. N., WOOD, K., JONES, S., & THOMPSON, R. W.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2000-09
- Volume
- 32
- Issue
- Supplement
- Pages
- S489-S497
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2119384593
- Cited by
- 343
- References
- 4
- FWCI
- 5.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparative evaluation of three accelerometry-based physical activity monitors. https://app.cochat.ai/papers/10.1097/00005768-200009001-00008
- The paper
- WELK, G. J., BLAIR, S. N., WOOD, K., JONES, S., & THOMPSON, R. W. (2000). A comparative evaluation of three accelerometry-based physical activity monitors. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-200009001-00008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.