Dual x-ray absorptiometry, bioelectrical impedance, and near infrared interactance in obese women
The DOI matches its Crossref record.
Abstract
PANOTOPOULOS, G., J. C. RUIZ, B. GUY-GRAND, and A. BASDEVANT. Dual x-ray absorptiometry, bioelectrical impedance, and near infrared interactance in obese women. Med. Sci. Sports Exerc., Vol. 33, No. 4, 2001, pp. 665–670. Purpose: Whether the evaluation of body composition in obese people using low-cost, simple bedside, two-compartment techniques reflects the data obtained by indirect methods such as dual x-ray absorptiometry (DEXA) remains controversial. The aim of this study was to compare the data obtained by three methods of assessment of body composition (DEXA; bioelectrical impedance, BIA; and near infrared interactance, NII). Method: Data on body composition obtained in 53 obese women by these three methods were compared, using the Bland and Altman procedure to test the relative validity. Results: Although the correlation coefficients between DEXA and the two other methods were high, there were some major differences (limits of agreement) between data concerning fat and lean mass. Conclusions: The present study indicates that these methods cannot be considered as interchangeable and raises some questions on the use of BIA and NII as a single method of evaluation of body composition in clinical research and practice in obese populations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sun, G., French, C. R., Martin, G. R., Younghusband, B., Green, R. C., Xie, Y.-G., Mathews, M., Barron, J. R., Fitzpatrick, D. G., Gulliver, W., et al. (2005) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/81.1.74 · Cited by 377
Achamrah, N., Colange, G., Delay, J., Rimbert, A., Folope, V., Petit, A., Grigioni, S., Déchelotte, P., & Coëffier, M. (2018) · PLoS ONE · doi:10.1371/journal.pone.0200465 · Cited by 337
The effects of obesity on pulmonary function
Li, A. M. (2003) · Archives of Disease in Childhood · doi:10.1136/adc.88.4.361 · Cited by 226
Shafer, K. J., Siders, W. A., Johnson, L. K., & Lukaski, H. C. (2009) · Nutrition · doi:10.1016/j.nut.2008.07.004 · Cited by 223
Validity and reliability of body composition analysers in children and adults
Jensky-Squires, N. E., Dieli-Conwright, C. M., Rossuello, A., Erceg, D. N., McCauley, S., & Schroeder, E. T. (2008) · British Journal of Nutrition · doi:10.1017/s0007114508925460 · Cited by 175
“(26) indicated that in obese women BIA, NIA and DEXA cannot be used interchangeably.”
Metadata
- Authors
- PANOTOPOULOS, G., CHARLES RUIZ, J., GUY-GRAND, B., & BASDEVANT, A.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2001-04
- Volume
- 33
- Issue
- 4
- Pages
- 665-670
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2013574106
- Cited by
- 59
- References
- 0
- FWCI
- 1.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dual x-ray absorptiometry, bioelectrical impedance, and near infrared interactance in obese women. https://app.cochat.ai/papers/10.1097/00005768-200104000-00024
- The paper
- PANOTOPOULOS, G., CHARLES RUIZ, J., GUY-GRAND, B., & BASDEVANT, A. (2001). Dual x-ray absorptiometry, bioelectrical impedance, and near infrared interactance in obese women. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-200104000-00024
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.