Measurement of the mechanical power of walking by satellite positioning system (GPS)
Open accessThe DOI matches its Crossref record.
Abstract
PURPOSE: This descriptive article illustrates the application of Global Positioning System (GPS) professional receivers in the field of locomotion studies. The technological challenge was to assess the external mechanical work in outdoor walking. METHODS: Five subjects walked five times during 5 min on an athletic track at different imposed stride frequency (from 70-130 steps x min(-1)). A differential GPS system (carrier phase analysis) measured the variation of the position of the trunk at 5 Hz. A portable indirect calorimeter recorded breath-by-breath energy expenditure. RESULTS: For a walking speed of 1.05 +/- 0.11 m x s(-1), the vertical lift of the trunk (43 +/- 14 mm) induced a power of 46.0 +/- 20.4 W. The average speed variation per step (0.15 +/- 0.03 m x s(-1)) produced a kinetic power of 16.9 +/- 7.2 W. As compared with commonly admitted values, the energy exchange (recovery) between the two energy components was low (39.1 +/- 10.0%), which induced an overestimated mechanical power (38.9 +/- 18.3 W or 0.60 W x kg(-1) body mass) and a high net mechanical efficiency (26.9 +/- 5.8%). CONCLUSION: We assumed that the cause of the overestimation was an unwanted oscillation of the GPS antenna. It is concluded that GPS (in phase mode) is now able to record small body movements during human locomotion, and constitutes a promising tool for gait analysis of outdoor unrestrained walking. However, the design of the receiver and the antenna must be adapted to human experiments and a thorough validation study remains to be conducted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Applications of GPS Technologies to Field Sports
Aughey, R. J. (2011) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.6.3.295 · Cited by 468
Qasem, L., Cardew, A., Wilson, A., Griffiths, I., Halsey, L. G., Shepard, E. L. C., Gleiss, A. C., & Wilson, R. (2012) · PLoS ONE · doi:10.1371/journal.pone.0031187 · Cited by 399
“Beyond these approaches, however, some researchers have examined the use of mechanical motion sensors [26,27] in studies”
BackgroundAinslie, P. N., Reilly, T., & Westerterp, K. R. (2003) · Sports Medicine · doi:10.2165/00007256-200333090-00004 · Cited by 309
Effects of Intermittent-Endurance Fitness on Match Performance in Young Male Soccer Players
Castagna, C., Impellizzeri, F., Cecchini, E., Rampinini, E., & Alvarez, J. C. B. (2009) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181b7f743 · Cited by 253
Accuracy of non-differential GPS for the determination of speed over ground
Witte, T. H., & Wilson, A. M. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.031 · Cited by 222
Metadata
- Authors
- TERRIER, P., LADETTO, Q., MERMINOD, B., & SCHUTZ, Y.
- Venue
- Medicine and Science in Sports and Exercise
- Published
- 2001-11
- Volume
- 33
- Issue
- 11
- Pages
- 1912-1918
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2023169634
- Cited by
- 59
- References
- 0
- FWCI
- 2.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of the mechanical power of walking by satellite positioning system (GPS). https://app.cochat.ai/papers/10.1097/00005768-200111000-00017
- The paper
- TERRIER, P., LADETTO, Q., MERMINOD, B., & SCHUTZ, Y. (2001). Measurement of the mechanical power of walking by satellite positioning system (GPS). Medicine and Science in Sports and Exercise. https://doi.org/10.1097/00005768-200111000-00017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.