Effect of cycling experience and pedal cadence on the near-infrared spectroscopy parameters
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Purpose Previously we demonstrated that the method to reorder near-infrared spectroscopy (NIRS) parameters against crank angle could serve as a useful measure in providing circulatory dynamics and metabolic changes in a working muscle during pedaling exercise. To examine further applicability of this method, we investigated the effects of cycling experience and pedal cadence on the NIRS parameters. Methods Noncyclists (NON), triathletes (TRI), and cyclists (CYC) performed pedaling exercises at a work intensity of 75% VO2max while changing pedal cadence (50, 75, 85, and 95 rpm). Physiological and biomechanical responses and NIRS parameters were measured. Results NIRS measurements determined with the reordered NIRS change demonstrated significant differences depending on the factors. The bottom peak of reordered NIRS changes in muscle blood volume and oxygenation level shifted upward with an increase in pedal cadence in NON but remained unchanged in CYC. The reordered NIRS change demonstrated a temporary increase at the crank angle corresponding to the relaxation phase of the working muscle. This temporary increase was observed even in the highest pedal cadence in CYC. The difference in levels between the peak of the temporary increase and the bottom peak of reordered NIRS change (LPB-diff) for CYC at 85 rpm was significantly larger than that for NON. The results with NIRS parameters corresponded to changes in pedal force and myoelectric activity during pedal thrust. Conclusion…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This cutoff was selected to minimize the effect of changing cadence on SmO2 (45).”
From Comparing the reliability of muscle oxygen saturation with common performance and physiological markers across cycling exercise intensity (2023) · cites this paper as [45]
Citations
Cites
Data on the distribution of fibre types in thirty-six human muscles
Johnson, M. A., Polgar, J., Weightman, D., & Appleton, D. (1973) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(73)90023-3 · Cited by 2,200
Adaptations of skeletal muscle to endurance exercise and their metabolic consequences
Holloszy, J. O., & Coyle, E. F. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.56.4.831 · Cited by 1,985
Physiological and biomechanical factors associated with elite endurance cycling performance
COYLE, E. F., FELTNER, M. E., KAUTZ, S. A., HAMILTON, M. T., MONTAIN, S. J., BAYLOR, A. M., ABRAHAM, L. D., & PETREK, G. W. (1991) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199101000-00015 · Cited by 551
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528
Hoppeler, H., L�thi, P., Claassen, H., Weibel, E. R., & Howald, H. (1973) · Pfl�gers Archiv European Journal of Physiology · doi:10.1007/bf00588462 · Cited by 443
Determinants of endurance in well-trained cyclists
Coyle, E. F., Coggan, A. R., Hopper, M. K., & Walters, T. J. (1988) · Journal of Applied Physiology · doi:10.1152/jappl.1988.64.6.2622 · Cited by 438
The Nature of the Training Response; Peripheral and Central Adaptations to One‐Legged Exercise
Saltin, B., Nazar, K., Costill, D. L., Stein, E., Jansson, E., Essén, B., & Gollnick, P. D. (1976) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1976.tb10200.x · Cited by 412
Intramuscular fluid pressure during isometric contraction of human skeletal muscle
Sejersted, O. M., Hargens, A. R., Kardel, K. R., Blom, P., Jensen, O., & Hermansen, L. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.56.2.287 · Cited by 355
Skeletal muscle tension, flow, pressure, and EMG during sustained isometric contractions in humans
Sadamoto, T., Bonde-Petersen, F., & Suzuki, Y. (1983) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00429076 · Cited by 322
Muscular endurance and surface electromyogram in isometric and dynamic exercise
Hagberg, M. (1981) · Journal of Applied Physiology · doi:10.1152/jappl.1981.51.1.1 · Cited by 316
Research works printed but not linked: 4
- Brodal, 1977, Am J Physiol, 232, H705
- Laughlin, 1987, Am J Physiol, 253, H993
- L??llgen, 1980, Med Sci Sports Exerc, 12, 345, 10.1249/00005768-198025000-00008 · doi:10.1249/00005768-198025000-00008 · Paper page
- Mackie, 1983, Am J Physiol, 245, H265
Cited by
Models to Explain Fatigue during Prolonged Endurance Cycling
Abbiss, C. R., & Laursen, P. B. (2005) · Sports Medicine · doi:10.2165/00007256-200535100-00004 · Cited by 388
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
The Science of Cycling: Physiology and Training ??? Part 1
Faria, E. W., Parker, D. L., & Faria, I. E. (2005) · Sports Medicine · doi:10.2165/00007256-200535040-00002 · Cited by 315
Application of Near Infrared Spectroscopy to Exercise Sports Science
Neary, J. P. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-032 · Cited by 73
Strategies for Improving Performance in Long Duration Events: Olympic Distance Triathlon
Hausswirth, C., & Brisswalter, J. (2008) · Sports Medicine · doi:10.2165/00007256-200838110-00001 · Cited by 87
Effects of pedal frequency on estimated muscle microvascular O2 extraction
Ferreira, L. F., Lutjemeier, B. J., Townsend, D. K., & Barstow, T. J. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0107-3 · Cited by 63
Gómez‐Carmona, C. D., Bastida‐Castillo, A., Rojas‐Valverde, D., Sánchez, E. D. L. C., García-Rubio, J., Ibáñez, S. J., & Pino‐Ortega, J. (2019) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000003400 · Cited by 55
Which factors determine the freely chosen cadence during submaximal cycling?
Vercruyssen, F., & Brisswalter, J. (2009) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2008.12.631 · Cited by 51
Yogev, A., Arnold, J., Nelson, H., Clarke, D. C., Guenette, J. A., Sporer, B. C., & Koehle, M. S. (2023) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2023.1143393 · Cited by 49
Kounalakis, S. N., & Geladas, N. D. (2012) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h2012-011 · Cited by 38
Skovereng, K., Ettema, G. J. C., & Beekvelt, M. C. P. V. (2016) · European Journal of Applied Physiology · doi:10.1007/s00421-016-3379-x · Cited by 35
Physiological adaptation during short distance triathlon swimming and cycling sectors simulation
González‐Haro, C., de Suso, J. M. G., Padullés, J. M., Drobnic, F., & Escanero, J. F. (2005) · Physiology & Behavior · doi:10.1016/j.physbeh.2005.08.029 · Cited by 34
Maximal lactate steady state concentration independent of pedal cadence in active individuals
Denadai, B. S., Ruas, V. D. D. A., & Figueira, T. R. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0090-8 · Cited by 32
Choo, H. C., Nosaka, K., Peiffer, J. J., Ihsan, M., Yeo, C. C., & Abbiss, C. R. (2016) · Journal of Sports Sciences · doi:10.1080/02640414.2016.1235790 · Cited by 26
Denadai, B. S., Ruas, V. D. D. A., & Figueira, T. R. (2005) · Revista Brasileira de Medicina do Esporte · doi:10.1590/s1517-86922005000500008 · Cited by 25
NIRS application in evaluating threaded-fastener driving assembly tasks
Lin, J., Maikala, R. V., McGorry, R. W., & Brunette, C. M. (2009) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2008.12.005 · Cited by 21
NIRS Measurements with Elite Speed Skaters: Comparison Between the Ice Rink and the Laboratory
Hesford, C., Cardinale, M., Laing, S. J., & Cooper, C. E. (2012) · Advances in experimental medicine and biology · doi:10.1007/978-1-4614-4989-8_12 · Cited by 20
Breese, B. C., Armstrong, N., BARKER, A. R., & Williams, C. A. (2011) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2011.03.018 · Cited by 19
The Effect of Cadence on Cycling Efficiency and Local Tissue Oxygenation
Jacobs, R. D., Berg, K. E., Slivka, D. R., & Noble, J. M. (2012) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e31825dd224 · Cited by 19
Skeletal muscle oxygenation during cycling at different power output and cadence
Shastri, L., Alkhalil, M., Forbes, C., El-Wadi, T., Rafferty, G. F., Ishida, K., & Formenti, F. (2019) · Physiological Reports · doi:10.14814/phy2.13963 · Cited by 18
Self-citationThe role of muscle pump in the development of cardiovascular drift
Kounalakis, S. N., Keramidas, M. E., Nassis, G. P., & Geladas, N. D. (2008) · European Journal of Applied Physiology · doi:10.1007/s00421-007-0662-x · Cited by 18
Gandía-Soriano, A., Salas-Montoro, J.-A., Javaloyes, A., Lorente-Casaus, C., Zabala, M., Priego‐Quesada, J. I., & Mateo‐March, M. (2022) · International Journal of Sports Medicine · doi:10.1055/a-1828-8499 · Cited by 18
Hirano, M., Shindo, M., Mishima, S., Morimura, K., Higuchi, Y., Yamada, Y., Higaki, Y., & Kiyonaga, A. (2014) · European Journal of Applied Physiology · doi:10.1007/s00421-014-3081-9 · Cited by 16
Formenti, F., Dockerill, C., Kankanange, L., Zhang, L., Takaishi, T., & Ishida, K. (2019) · International Journal of Sports Medicine · doi:10.1055/a-0835-6286 · Cited by 16
Self-citationReproducibility of Measurement of Muscle Deoxygenation in Children During Exercise
Leclair, E., Thévenet, D., Reguem, S. C., Borel, B., Baquet, G., Berthoin, S., & Mucci, P. (2010) · Pediatric Exercise Science · doi:10.1123/pes.22.2.183 · Cited by 15
Muscle oxygenation in response to high intensity interval exercises among high trained judokas
Kujach, S., Ziemann, E., Grzywacz, T., Łuszczyk, M., Smaruj, M., Dzedzej, A., & Laskowski, R. (2016) · Isokinetics and Exercise Science · doi:10.3233/ies-160631 · Cited by 9
Saito, A., Goda, M., Yamagishi, T., & Kawakami, Y. (2018) · Physiological Reports · doi:10.14814/phy2.13832 · Cited by 8
Mañas, E. M., Llana‐Belloch, S., Úbeda-Pastor, V., & García‐Massó, X. (2021) · Sports Biomechanics · doi:10.1080/14763141.2021.1968480 · Cited by 5
EFFECT OF PEDAL RATE AND TORQUE ON MUSCLE OXYGENATION AND ENERGY METABOLISM
Wang, L., Yoshikawa, T., Hara, T., Nakao, H., Suzuki, T., & Fujimoto, S. (2005) · 体力科學 · doi:10.7600/jspfsm.54.229 · Cited by 4
Cardiovascular Responses Between Low Cadence/High Force vs. High Cadence/Low Force Cycling
Canivel, R. G., & Wyatt, F. (2016) · International journal of exercise science · doi:10.70252/opnx5162 · Cited by 4
Riesco-Villar, J., Escribano-Pascual, A., González-Fernández, A., Pascual-Redondo, H., Gil-Calvo, M., & Boullosa, D. A. (2025) · European Journal of Applied Physiology · doi:10.1007/s00421-025-05794-2 · Cited by 3
Gómez-Carmona, C. D., Bastida‐Castillo, A., & Pino‐Ortega, J. (2019) · Revista Andaluza de Medicina del Deporte · doi:10.33155/j.ramd.2017.007.003 · Cited by 3
The effects of altered heat stress on voluntary pacing strategies during prolonged cycling
Hartley, G. L. (2009) · Brock University Digital Repository (Brock University) · Cited by 2
Cortés Mollá, J. S. (2016) · Repository of Digital Objects for Teaching Research and Culture (University of Valencia) · Cited by 1
Hahn, D. (2015) · Texas ScholarWorks (Texas Digital Library) · doi:10.15781/t25w3q
Amorim, N. M. M. (2017) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/zage-vm25
Chroboczek, M., Jakubowska, M., Kujach, S., Łuszczak, M., & Laskowski, R. (2017) · Baltic Journal of Health and Physical Activity · doi:10.29359/bjhpa.09.3.06
Whitty, A. G. (2017) · OPUS - Open Publications of UTS Scholars (University of Technology Sydney)
強度漸減・高強度・短時間・間欠的自転車運動トレーニングが最大酸素摂取量及び筋機能に及ぼす影響に関する研究
苫米地, 伸. (2019) · Institutional Repositories DataBase (IRDB) · doi:10.14943/doctoral.k13625
Cesanelli, L., Ylaitė, B., Leite, N. M. C., & Calleja-González, J. (2021) · Journal Of Science & Cycling · doi:10.28985/1221.jsc.02
鉄雄, 高., & 敏夫, 森. (2007) · 体力科學 · doi:10.7600/jspfsm.56.100
Apnea. Una alternativa a la hipoxia para mejorar el rendimiento en ciclismo
Salas-Montoro, J.-A. (2023) · Institutional Repository of the University of Granada (University of Granada) · doi:10.13140/rg.2.2.31471.00163
Riesco-Villar, J. (2024) · Buleria (Universidad de León)
Ruas, V. D. D. A. (2007) · Americanae (AECID Library)
Born, D. P. (2015) · Online Publication Service of Würzburg University (Würzburg University)
Vidotto, L. S. (2014) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Muscle Oxygenation During Exercise in Patients with Peripheral Artery Disease: A Systematic Review
Salamifar, Z., Fallahtafti, F., Pipinos, I. I., Anderson, C. P., Park, S., & Myers, S. A. (2026) · Applied Sciences · doi:10.3390/app16094348
Mañas, E. M., Llana‐Belloch, S., Monfort-Torres, G., & García‐Massó, X. (2026) · Methods and Protocols · doi:10.3390/mps9040118
Ruas, V. D. D. A. (2007) · Aleph UCLA Undergraduate Research Journal for the Humanities and Social Sciences
Metadata
- Authors
- TAKAISHI, T., ISHIDA, K., KATAYAMA, K., YAMAZAKI, K., YAMAMOTO, T., & MORITANI, T.
- Affiliations
- Kyoto University (JP)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2002-12
- Volume
- 34
- Issue
- 12
- Pages
- 2062-2071
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2055475719
- Semantic Scholar
- ce10e8eb960248fa25089008bdd79fa5c97730dc
- Cited by
- 38
- References
- 27
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 1 · 2022: 1 · 2021: 2 · 2019: 4 · 2018: 1 · 2017: 1 · 2016: 3 · 2014: 1 · 2012: 3
- FWCI
- 6.08
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Keywords
- near-infrared spectroscopy, pedal cadence, cycling experience, muscle blood volume, muscle oxygenation, crank angle, cycling exercise, endurance cycling, triathletes, muscle relaxation, pedal force, muscle electrical activity, circulatory dynamics, muscle metabolism
- MeSH terms
- Adaptation, Physiological, Adult, Bicycling, Biomechanical Phenomena, Blood Volume, Electromyography, Energy Metabolism, Heart Rate, Humans, Male, Oxygen Consumption, Exercise Tolerance, Muscle, Skeletal, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.