VALIDATION OF ENERGY EXPENDITURE PREDICTION ALGORITHMS IN ADULTS USING THE ACTICAL ELECTRONIC ACTIVITY MONITOR
The DOI matches its Crossref record.
Abstract
PURPOSE The purpose of this study was to validate the use of the Actical (Mini Mitter Co., Inc., Bend, OR) electronic activity monitor for predicting energy expenditure (EE) in healthy adults. METHODS Twelve men (Mean±SD: 33.5±7.8 yrs, 83.0±8.7 kg) and 12 women (39.3±10.2 yrs, 68.9±5.3 kg) visited the lab once to perform 9 activities: Typing, hand writing, card sorting, floor sweeping, carpet vacuuming, table surface dusting, and treadmill walking (5 mins each at 67 and 80.4 m/min) and jogging (5 mins at 120.6 m/min). Subjects wore Actical monitors on the non-dominant wrist, on the ankle of the same side of the body, and on the right hip just posterior to the iliac crest during all activities. Actual EE was determined using the VmaxST portable metabolic system (SensorMedics Corp., Yorba Linda, CA) which was carried in a small pack and worn on the back during all activities (equipment mass = 1.14 kg). The last two 60 sec sample averages from both the metabolic system (units of METs) and the Actical monitors (units of counts/min) were extracted from the raw data and used to generate separate MET prediction algorithms (standard linear regression procedures) for each monitor location. Each algorithm included: 1) Lower Actical cutoff value (< 250–500 counts/min; no prediction equation applied); 2) Equation predicting METs between the lower cutoff and an upper cutoff (1200–1500 counts/min); 3) Equation predicting METs higher than the upper cutoff. Predicted METs from each algorithm was compared with actual METs using PPM correlations, SEE, and standard residual analyses. RESULTS Algorithms for the ankle (R = 0.77, SEE = ±1.4 METs, P < 0.001), hip (R = 0.94, SEE = ±0.8 METs, P < 0.001), and wrist (R = 0.90, SEE = ±1.0 METs, P < 0.001) monitors provided reasonably accurate predictions of METs. CONCLUSIONS Though the hip and wrist locations appear to be most promising, further research should verify this in field settings. This study was funded by a grant from the Mini Mitter Co., Bend, OR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Estimating energy expenditure using accelerometers
Crouter, S. E., Churilla, J. R., & Bassett, D. R. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0307-5 · Cited by 366
Murphy, S. L. (2009) · Preventive Medicine · doi:10.1016/j.ypmed.2008.12.001 · Cited by 326
Accuracy of the Actiheart for the assessment of energy expenditure in adults
Crouter, S. E., Churilla, J. R., & Bassett, D. R. (2008) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602766 · Cited by 236
Lyden, K., Kozey, S. L., Staudenmeyer, J. W., & Freedson, P. S. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1639-8 · Cited by 222
“…£ 10¡12 £ (cnts min¡1)3] METs Klippel and Heil (2003) (1R) 24 Actical cnts min¡1 · 50; EE = 1 MET 50 < cnts min¡1 < 350; EE = 1.83 METs 350 < cnts min¡1; 2.826 + (0.0006526 £ cnts min¡1) METs Klippel and Heil (2003) (2R) 24 Actical cnts min¡1 · 50; EE = 1 MET 50 < cnts min¡1 < 350; EE = 1.83…”
Influential
Metadata
- Authors
- Klippel, N. J., & Heil, D. P.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2003-05
- Volume
- 35
- Issue
- Supplement 1
- Pages
- S284
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2055801853
- Cited by
- 44
- References
- 0
- Type
- conference abstract
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: VALIDATION OF ENERGY EXPENDITURE PREDICTION ALGORITHMS IN ADULTS USING THE ACTICAL ELECTRONIC ACTIVITY MONITOR. https://app.cochat.ai/papers/10.1097/00005768-200305001-01580
- The paper
- Klippel, N. J., & Heil, D. P. (2003). VALIDATION OF ENERGY EXPENDITURE PREDICTION ALGORITHMS IN ADULTS USING THE ACTICAL ELECTRONIC ACTIVITY MONITOR. Medicine & Science in Sports & Exercise. https://doi.org/10.1097/00005768-200305001-01580
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.