Abstract
One of the potential variables affecting the overall survival and quality of life of patients with intracranial gliomas is the extent of tumor resection that results in the smallest volume of residual disease. A technique involving enhanced optical imaging of human gliomas has the potential to localize tumors, identify tumor remaining at the resection margins, and determine the grade of the tumor. In a preliminary study involving nine patients undergoing surgery for the removal of intrinsic brain tumors, enhanced optical imaging was performed using indocyanine green as an intravenous contrast-enhancement agent. Optical images were obtained before and after injection of the indocyanine green. The studies in the nine patients showed differences in the dynamic optical signals among normal brain, low-grade astrocytomas, and malignant astrocytomas. Optical imaging of the resection margins in malignant tumors showed differences between adjacent normal tissue and remaining tumor tissue. Enhanced optical imaging of human gliomas using a contrast-enhancing dye, indocyanine green, provides a potential means to differentiate between normal brain and tumor tissue at the cortical surface and the depths of the resection margins. Having the ability to obtain real-time information and feedback in the operating room may allow neurosurgeons to maximize the extent of tumor resection while sparing normal brain and increasing the diagnostic accuracy of intraoperative biopsies. Enhanced optical imaging potentially could facilitate the accuracy and safety of surgery when tumors are removed at sites even outside the central nervous system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
In vivo near-infrared fluorescence imaging
Frangioni, J. V. (2003) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2003.08.007 · Cited by 2,653
Vieira, D., & Gamarra, L. (2016) · International Journal of Nanomedicine · doi:10.2147/ijn.s117210 · Cited by 427
Molecular imaging for cancer diagnosis and surgery
Hussain, T., & Nguyen, Q. T. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.09.007 · Cited by 337
Fluorescence-enhanced, near infrared diagnostic imaging with contrast agents
Sevick-Muraca, E. M., Houston, J. P., & Gurfinkel, M. (2002) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(02)00356-3 · Cited by 328
Optical imaging in drug discovery and diagnostic applications
LICHA, K., & OLBRICH, C. (2005) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2005.01.021 · Cited by 263
Metadata
- Authors
- Haglund, M. M., Berger, M. S., & Hochman, D. W.
- Venue
- Neurosurgery
- Published
- 1996-02-01
- Volume
- 38
- Issue
- 2
- Pages
- 308-317
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W2044588951
- Cited by
- 184
- References
- 0
- FWCI
- 3.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced Optical Imaging of Human Gliomas and Tumor Margins. https://app.cochat.ai/papers/10.1097/00006123-199602000-00015
- The paper
- Haglund, M. M., Berger, M. S., & Hochman, D. W. (1996). Enhanced Optical Imaging of Human Gliomas and Tumor Margins. Neurosurgery. https://doi.org/10.1097/00006123-199602000-00015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.