Transcranial High-frequency Repetitive Electrical Stimulation for Recording Myogenic Motor Evoked Potentials with the Patient under General Anesthesia

Pechstein, Ulrich, Ceclzich, Cornelia, Nadstawek, Joachim, Schramm, Johannes·1996·Neurosurgery

Abstract

OBJECTIVE: To demonstrate the feasibility of transcranial high-frequency electrical stimulation with the patient under general anesthesia with propofol and alfentanil. This method may be a useful tool for intraoperative monitoring of the motor pathways during cerebral and spinal operations. METHODS: A short train from one to eight monopolar anodal electrical pulses was applied transcranially to the motor cortex with a frequency from 100 to 500 Hz in 10 patients. Myogenic motor evoked potentials (MEPs) were recorded from forearm flexor muscles, thenar, and hypothenar. Amplitude and latency of MEPs were evaluated after different stimulation parameters. This combination of anesthetic and transcranial stimulation technique allows recording of myogenic MEPs during general anesthesia, which was found not to be possible with single pulse transcranial stimulation. RESULTS: To elicit myogenic MEPs from the target muscles, stimulation had to be applied within the following parameters: minimum threshold intensity was 60 mA for forearm flexor and thenar and 80 mA for hypothenar; minimum number of pulses was two for forearm flexor muscles and thenar and three for hypothenar; minimum stimulation frequency was 200 Hz for thenar and hypothenar and 100 Hz for forearm flexor muscles. CONCLUSION: Transcranial high-frequency repetitive electrical stimulation seems to be a new method for monitoring the motor tract. With this method, it is possible to monitor the motor function without interfering with the surgical team or with the surgical treatment of infratentorial and spinal lesions. Monitoring of relaxation is necessary to compare the amplitude of MEPs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00006123-199608000-00020

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Metadata

Authors
Pechstein, U., Ceclzich, C., Nadstawek, J., & Schramm, J.
Venue
Neurosurgery
Published
1996-08-01
Volume
39
Issue
2
Pages
335-344
ISSN
  • 0148-396X (ISSN-L)
  • 1524-4040
OpenAlex
W2052512458
Cited by
246
References
1
FWCI
8.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transcranial High-frequency Repetitive Electrical Stimulation for Recording Myogenic Motor Evoked Potentials with the Patient under General Anesthesia. https://app.cochat.ai/papers/10.1097/00006123-199608000-00020
The paper
Pechstein, U., Ceclzich, C., Nadstawek, J., & Schramm, J. (1996). Transcranial High-frequency Repetitive Electrical Stimulation for Recording Myogenic Motor Evoked Potentials with the Patient under General Anesthesia. Neurosurgery. https://doi.org/10.1097/00006123-199608000-00020

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.