The DOI matches its Crossref record.
Use of Factor IX Complex in Warfarin-related Intracranial Hemorrhage
Abstract
OBJECTIVE: Anticoagulation-treated patients presenting with intracranial hemorrhage, including subdural hematoma, epidural hematoma, subarachnoid hemorrhage, and intracerebral hemorrhage, require urgent correction of their coagulopathy to prevent worsening hemorrhage and to facilitate surgical intervention when necessary. In this study, we compared the use of fresh frozen plasma (FFP) with that of Factor IX complex concentrate (FIXCC) to achieve rapid correction of warfarin anticoagulation. METHODS: Patients admitted to a tertiary care center with computed tomography-proven intracranial hemorrhage and a prothrombin time of more than 17 seconds were considered for inclusion in the study protocol. Complete data sets were obtained for eight patients randomized to treatment with FFP and five patients randomized to treatment with FFP supplemented with FIXCC. The prothrombin time and International Normalized Ratio were measured every 2 hours for 14 hours. Correction of anticoagulation was defined as an International Normalized Ratio of < or =1.3. RESULTS: A difference in repeated International Normalized Ratio measurements during the first 6 hours of correction was observed between the FIXCC and FFP groups (P < 0.03). The rate of correction was greater (P < 0.01) and the time to correction was shorter (P < 0.01) for the FIXCC-treated group. No difference in neurological outcomes was detected between groups, but a higher complication rate was observed for the FFP-treated group. CONCLUSION: The use of FIXCC accelerated correction of warfarin-related anticoagulation in the presence of intracranial hemorrhage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hemphill, J. C., Greenberg, S. M., Anderson, C. S., Becker, K., Bendok, B. R., Cushman, M., Fung, G. L., Goldstein, J. N., Macdonald, R. L., Mitchell, P. H., et al. (2015) · Stroke · doi:10.1161/str.0000000000000069 · Cited by 3,994
Morgenstern, L. B., Hemphill, J. C., Anderson, C., Becker, K., Broderick, J. P., Connolly, E. S., Greenberg, S. M., Huang, J. N., Macdonald, R. L., Messé, S. R., et al. (2010) · Stroke · doi:10.1161/str.0b013e3181ec611b · Cited by 1,496
Evidence-Based Management of Anticoagulant Therapy
Holbrook, A., Schulman, S., Witt, D. M., Vandvik, P. O., Fish, J., Kovacs, M. J., Svensson, P. J., Veenstra, D. L., Crowther, M., & Guyatt, G. H. (2012) · Chest · doi:10.1378/chest.11-2295 · Cited by 1,269
Broderick, J., Connolly, S., Feldmann, E., Hanley, D., Kase, C., Krieger, D., Mayberg, M., Morgenstern, L., Ogilvy, C. S., Vespa, P., et al. (2007) · Stroke · doi:10.1161/strokeaha.107.183689 · Cited by 1,125
Sarode, R., Milling, T. J., Refaai, M. A., Mangione, A., Schneider, A., Durn, B. L., & Goldstein, J. N. (2013) · Circulation · doi:10.1161/circulationaha.113.002283 · Cited by 813
Metadata
- Authors
- Boulis, N. M., Bobek, M. P., Schmaier, A., & Hoff, J. T.
- Venue
- Neurosurgery
- Published
- 1999-11
- Volume
- 45
- Issue
- 5
- Pages
- 1113-1119
- ISSN
- 0148-396X (ISSN-L)
- 1524-4040
- OpenAlex
- W1986546417
- Cited by
- 215
- References
- 0
- FWCI
- 1.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of Factor IX Complex in Warfarin-related Intracranial Hemorrhage. https://app.cochat.ai/papers/10.1097/00006123-199911000-00020
- The paper
- Boulis, N. M., Bobek, M. P., Schmaier, A., & Hoff, J. T. (1999). Use of Factor IX Complex in Warfarin-related Intracranial Hemorrhage. Neurosurgery. https://doi.org/10.1097/00006123-199911000-00020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.