CoChat

Transradial Cerebral Angiography: An Alternative Route

Levy, Elad I., Boulos, Alan S., Fessler, Richard D., Bendok, Bernard R., Ringer, Andrew J., Kim, Stanley H., Qureshi, Adnan I., Guterman, Lee R., Hopkins, L. Nelson · 2002 · Neurosurgery
Cited by 196

The DOI matches its Crossref record.

Abstract

INTRODUCTION: The transradial approach has been well described for arteriography of the coronary vessels. To assess the safety and success rate of the transradial approach for three-vessel or four-vessel diagnostic cerebral arteriography, we reviewed the experience at our institution and compared our complication rates with those found in the literature for transfemoral cerebral angiography and transradial coronary angiography. METHODS: We reviewed the electronic medical records of 129 consecutive patients in whom 132 cerebral angiographic studies were performed by use of a transradial approach between December 1999 and June 2001. A total of 54 selective catheterizations were performed, of which 39 were of the vertebral artery, 11 of the internal carotid artery, and 4 of the external carotid artery. Records were reviewed for periprocedural and delayed complications, indications for diagnostic angiography, and requirement of conversion to a femoral approach. Records were reviewed prospectively for the first 55 procedures and retrospectively for the next 77 procedures. RESULTS: The mean time to initial clinical follow-up was 1.5 months (median, 0.5 mo). The combined rate of periprocedural and delayed complications was 9%, and there were no major complications. Minor periprocedural complications included transient radial artery spasm (four patients), failure to access the brachial artery (two patients), severe pain (one patient), skin desquamation (one patient), and hematoma (one patient). There were no major complications. At the time of follow-up evaluation, these patients were without deficits related to cannulation of the radial artery. CONCLUSION: The transradial approach for cerebral angiography is a safe alternative to the transfemoral route. After transradial cerebral angiography, patients require a shorter observation period and are not restricted to bed rest. As technological developments generate smaller, more pliable endovascular surgical devices, future endovascular surgery may be performed transradially.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00006123-200208000-00007

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 196

Metadata

Authors
Levy, E. I., Boulos, A. S., Fessler, R. D., Bendok, B. R., Ringer, A. J., Kim, S. H., Qureshi, A. I., Guterman, L. R., & Hopkins, L. N.
Venue
Neurosurgery
Published
2002-08
Volume
51
Issue
2
Pages
335-342
ISSN
0148-396X (ISSN-L)
OpenAlex
W2048478377
Cited by
196
References
0
FWCI
6.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transradial Cerebral Angiography: An Alternative Route. https://app.cochat.ai/papers/10.1097/00006123-200208000-00007
The paper
Levy, E. I., Boulos, A. S., Fessler, R. D., Bendok, B. R., Ringer, A. J., Kim, S. H., Qureshi, A. I., Guterman, L. R., & Hopkins, L. N. (2002). Transradial Cerebral Angiography: An Alternative Route. Neurosurgery. https://doi.org/10.1097/00006123-200208000-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.