CoChat

A threshold method to improve standardized uptake value reproducibility

LEE, J. R., MADSEN, M. T., BUSHNEL, D., MENDA, Y. · 2000 · Nuclear Medicine Communications
Cited by 70

The DOI matches its Crossref record.

Abstract

Although standardized uptake values (SUV) are widely used to quantify the uptake of 18F-fluorodeoxyglucose (18F-FDG) in tumours, there are systematic differences in the way this index is applied by different investigators. The aims of this study were to compare the effects of using maximum or mean region counts in the calculation of SUV and to investigate an alternative technique based on a fixed fraction of the maximum counts. Simulated PET projections of the thorax were generated together with spherical lesions that varied in diameter from 1.6 to 4.8 cm with uptake values of 2, 4 and 8. The lesion SUVs were determined using either the maximum (SUVmax) or mean count (SUVmean) values found in regions circumscribing the lesion. In addition, average values were calculated that only included region pixels that exceeded a selected fraction of maximum value (SUV0.6max or SUV0.75max). These methods were also applied to six clinical 18F-FDG PET studies with a total of 12 lesions. The SUVs for these lesions were determined independently by four observers. Decreases with respect to SUVmax of 57%, 23% and 14% were found for SUVmean, SUV0.6max and SUV0.75max approaches respectively in the simulation study. The variation in SUVmean with region size was 35%, while the SUV0.6max and SUV0.75max was less than 3%. Similar results were obtained for the clinical data. We conclude that the proposed technique produces SUVs that are essentially independent of lesion region size and shape. It is expected that this will provide a more stable and reliable result than current approaches.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00006231-200007000-00013

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 70

Metadata

Authors
LEE, J. R., MADSEN, M. T., BUSHNEL, D., & MENDA, Y.
Venue
Nuclear Medicine Communications
Published
2000-07
Volume
21
Issue
7
Pages
685-690
ISSN
0143-3636 (ISSN-L)
OpenAlex
W2330856853
Cited by
70
References
0
FWCI
1.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A threshold method to improve standardized uptake value reproducibility. https://app.cochat.ai/papers/10.1097/00006231-200007000-00013
The paper
LEE, J. R., MADSEN, M. T., BUSHNEL, D., & MENDA, Y. (2000). A threshold method to improve standardized uptake value reproducibility. Nuclear Medicine Communications. https://doi.org/10.1097/00006231-200007000-00013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.