CoChat

Gastric scintigraphy with a liquid–solid radiolabelled meal: performances of solid and liquid parameters

Couturier, Olivier, Bodet-Milin, Caroline, Querellou, Solène, Carlier, Thomas, Turzo, Alexandre, Bizais, Yves · 2004 · Nuclear Medicine Communications
Cited by 58

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

AIM: To assess the clinical performance of parameters of liquid-solid gastric emptying (GE) scintigraphy. METHODS: Fifty-three controls and 476 patients underwent GE scintigraphy using a liquid-solid test meal (non-ulcer dyspepsia, n=180; gastro-oesophageal reflux disease, n=123; dyspepsia after anti-reflux surgery, n=29; diabetes mellitus, n=96; cystic fibrosis prior to heart-lung transplantation, n=48). Time-activity curves were fitted by a power exponential function and half-emptying times (T1/2) were computed. The lag phase (Tlag) and constant emptying (TRE) times of solid emptying were also calculated using a mathematical method (maximum slope tangent method). RESULTS: TRE and T1/2 of solids were higher in each subgroup of patients vs. controls (P=0.0001) and in cystic fibrosis patients vs. gastro-oesophageal reflux patients (P=0.0001). Tlag was significantly higher only in non-ulcer dyspepsia patients vs. controls (P=0.001). There was no significant difference for liquid parameters. Using the mean+/-1.96 SD of the solid and liquid T1/2 values obtained in controls, GE was normal (n=251; 53%), delayed (n=183; 38%), accelerated (n=33; 7%) or mixed (n=9; 2%). Delayed solid T1/2 was the most prominent alteration (n=189), and alterations of liquid GE alone were present in only 24 (5%) patients. A good correlation was found between solid T1/2 and TRE (r=0.88), but no correlation between Tlag and TRE, suggesting that these estimates represent independent phases of GE. In 26 patients, all GE parameters of solids and liquids were normal except Tlag (n=8) or TRE (n=18). The lack of significant differences between the different patient subgroups did not allow emptying profiles to be drawn according to patient pathology. CONCLUSION: Liquid GE scintigraphy provided poor and unreliable information in terms of patient discrimination and the drawing of pathophysiological profiles of abnormal GE. Tlag and TRE may confirm GE alteration, especially when solid T1/2 values are at the superior limit of normality, and may improve the performance of GE scintigraphy, rather than using liquid parameters.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00006231-200411000-00013

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 58

Metadata

Authors
Couturier, O., Bodet-Milin, C., Querellou, S., Carlier, T., Turzo, A., & Bizais, Y.
Venue
Nuclear Medicine Communications
Published
2004-11
Volume
25
Issue
11
Pages
1143-1150
ISSN
0143-3636 (ISSN-L)
OpenAlex
W2009241890
Cited by
58
References
2
FWCI
3.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Gastric scintigraphy with a liquid–solid radiolabelled meal: performances of solid and liquid parameters. https://app.cochat.ai/papers/10.1097/00006231-200411000-00013
The paper
Couturier, O., Bodet-Milin, C., Querellou, S., Carlier, T., Turzo, A., & Bizais, Y. (2004). Gastric scintigraphy with a liquid–solid radiolabelled meal: performances of solid and liquid parameters. Nuclear Medicine Communications. https://doi.org/10.1097/00006231-200411000-00013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.