Accuracy and Safety of Transvaginal Sonographic Placental Localization
The DOI matches its Crossref record.
Abstract
Transvaginal sonographic localization of the placenta was performed in 100 patients suspected of having placenta previa. Except in one patient, the diagnosis was confirmed at cesarean delivery in all cases of placenta previa found by sonography before delivery, resulting in a 93.3% predictive value of a positive test. The predictive value of a negative test was 97.6%; in two patients a low-insertion placenta diagnosed by sonography was found to be a placenta previa at delivery. The sensitivity and specificity of the technique were 87.5 and 98.8%, respectively. Although in some instances transvaginal sonography was performed during vaginal hemorrhage, aggravation of bleeding was never observed. Transvaginal sonographic localization of the placenta proved to be an accurate and safe diagnostic procedure.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Overall, TVS has a high accuracy (positive predictive value of 93.3%, negative predictive value of 97.6% and false-negative rate of 2.33%) in predicting placenta praevia in women suspected of having a low-lying placenta on TAS in the second and early third trimester, with a sensitivity of 87.5% and a specificity of 98.8%.55”
From Placenta Praevia and Placenta Accreta: Diagnosis and Management: Green‐top Guideline No. 27a (2019) · cites this paper as [55]
Citations
Cites
Still being checked.
Cited by
Placenta Previa, Placenta Accreta, and Vasa Previa
Oyelese, Y., & Smulian, J. C. (2006) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000207559.15715.98 · Cited by 975
Abnormal Placentation: Placenta Previa, Vasa Previa, and Placenta Accreta
Silver, R. M. (2015) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000001005 · Cited by 519
Placenta Praevia and Placenta Accreta: Diagnosis and Management: Green‐top Guideline No. 27a
Jauniaux, E., Alfirevic, Z., Bhide, A., Belfort, M., Burton, G., Collins, S., Dornan, S., Jurkovic, D., Kayem, G., Kingdom, J., et al. (2019) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/1471-0528.15306 · Cited by 506
Persistence of Placenta Previa According to Gestational Age at Ultrasound Detection
Dashe, J. S., McIntire, D. D., Ramus, R. M., Santos-Ramos, R., & Twickler, D. M. (2002) · Obstetrics & Gynecology · doi:10.1097/00006250-200205000-00005 · Cited by 242
Epidemiology of placenta previa accreta: a systematic review and meta-analysis
Jauniaux, E., Grønbeck, L., Bunce, C., Langhoff-Roos, J., & Collins, S. L. (2019) · BMJ Open · doi:10.1136/bmjopen-2019-031193 · Cited by 200
Metadata
- Authors
- LEERENTVELD, R. A., GILBERTS, E. C. A. M., ARNOLD, M. J. C. W. J., & WLADIMIROFF, J. W.
- Affiliations
- Academisch Ziekenhuis Rotterdam (NL)
- Venue
- Obstetrics & Gynecology
- Published
- 1990-11
- Volume
- 76
- Issue
- 5
- Pages
- 759-762
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W2027669423
- Cited by
- 179
- References
- 0
- Citations by year
- 2026: 3 · 2025: 1 · 2024: 2 · 2023: 3 · 2022: 4 · 2021: 3 · 2020: 6 · 2019: 2 · 2018: 7 · 2017: 60 · 2016: 3 · 2015: 4 · 2014: 6 · 2013: 3 · 2012: 8
- FWCI
- 3.77
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Obstetrics and Gynecology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Maternal and fetal healthcare
- Health Sciences › Medicine › Obstetrics and Gynecology › Pregnancy and preeclampsia studies
- Health Sciences › Medicine › Obstetrics and Gynecology › Gynecological conditions and treatments
- Keywords
- placenta previa, transvaginal ultrasound, placental localization, diagnostic accuracy, sensitivity and specificity, predictive value, vaginal bleeding, cesarean section, diagnostic safety
- MeSH terms
- Cesarean Section, Female, Humans, Placenta, Placenta Previa, Predictive Value of Tests, Pregnancy, Sensitivity and Specificity, Ultrasonography, Prenatal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy and Safety of Transvaginal Sonographic Placental Localization. https://app.cochat.ai/papers/10.1097/00006250-199011000-00006
- The paper
- LEERENTVELD, R. A., GILBERTS, E. C. A. M., ARNOLD, M. J. C. W. J., & WLADIMIROFF, J. W. (1990). Accuracy and Safety of Transvaginal Sonographic Placental Localization. Obstetrics & Gynecology. https://doi.org/10.1097/00006250-199011000-00006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.