The DOI matches its Crossref record.
Comparison of 10% povidone-iodine and 0.5% chlorhexidine gluconate for the prevention of peripheral intravenous catheter colonization in neonates: a prospective trial
Abstract
The purpose of the study was to compare the efficacy of 10% povidone-iodine with that of 0.5% chlorhexidine gluconate in 70% isopropyl alcohol for the prevention of peripheral intravenous catheter colonization in neonates. This was a multicenter, nonrandomized prospective study in a tertiary neonatal intensive care setting in which povidone-iodine and chlorhexidine gluconate were each used as antiseptic skin preparations over sequential 6-month periods. During the first 6 months of the study when povidone-iodine was in use 9.3% (38 of 408) of catheters were colonized. During the second 6 months of the study when chlorhexidine gluconate was in use, catheter colonization occurred in 4.7% (20 of 418, P = 0.01). Catheter-related bacteremia occurred during only 0.2% (2 of 826) of all catheterizations. Heavy skin colonization before catheter insertion (relative risk, 3.6; 95% confidence interval, 1.9, 7.0), catheterization > or = 72 hours (relative risk. 2.0; 95% confidence interval, 1.01, 3.8) and gestational age < or = 32 weeks (relative risk, 1.8; 95% confidence interval, 1.02, 3.3) increased colonization risk. Ampicillin infusion (relative risk, 0.4; 95% confidence interval, 0.2, 0.7) and 0.5% chlorhexidine gluconate cutaneous antisepsis (relative risk, 0.4; 95% confidence interval, 0.2, 0.8) were factors associated with decreased colonization risk. We conclude that 0.5% chlorhexidine gluconate in 70% isopropyl alcohol appears to be more efficacious than 10% povidone-iodine for the prevention of peripheral intravenous catheter colonization in neonates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Self-citationGuidelines for the prevention of intravascular catheter-related infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.01.003 · Cited by 1,066
Self-citationGuidelines for the Prevention of Intravascular Catheter–Related Infections
O’Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Infection Control and Hospital Epidemiology · doi:10.1086/502007 · Cited by 847
Guidelines for the Prevention of Intravascular Catheter-Related Infections
O’Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Pediatrics · doi:10.1542/peds.110.5.e51 · Cited by 738
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir138 · Cited by 560
Self-citation
Metadata
- Authors
- GARLAND, J. S., BUCK, R. K., MALONEY, P., DURKIN, D. M., TOTH-LLOYD, S., DUFFY, M., SZOCIK, P., MCAULIFFE, T. L., & GOLDMANN, D.
- Venue
- The Pediatric Infectious Disease Journal
- Published
- 1995-06
- Volume
- 14
- Issue
- 6
- Pages
- 510-516
- ISSN
- 0891-3668 (ISSN-L)
- OpenAlex
- W2051041042
- Cited by
- 162
- References
- 0
- FWCI
- 7.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of 10% povidone-iodine and 0.5% chlorhexidine gluconate for the prevention of peripheral intravenous catheter colonization in neonates: a prospective trial. https://app.cochat.ai/papers/10.1097/00006454-199506000-00008
- The paper
- GARLAND, J. S., BUCK, R. K., MALONEY, P., DURKIN, D. M., TOTH-LLOYD, S., DUFFY, M., SZOCIK, P., MCAULIFFE, T. L., & GOLDMANN, D. (1995). Comparison of 10% povidone-iodine and 0.5% chlorhexidine gluconate for the prevention of peripheral intravenous catheter colonization in neonates: a prospective trial. The Pediatric Infectious Disease Journal. https://doi.org/10.1097/00006454-199506000-00008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.