Large-Volume Suction Lipectomy: An Analysis of 108 Patients
The DOI matches its Crossref record.
Abstract
Suction lipectomy was initially advocated for the treatment of localized collections of fat and for the removal of less than 1500 ml of material. However, many patients wished to have multiple areas treated or had diffuse collections of fat. In such instances, the removal of over 1500 ml of material and circumferential lipectomy are necessary to provide optimal aesthetic results. However, when over 1500 ml of material is removed, anesthetic requirements, fluid replacement, and treatment of blood loss become important if the operation is to be performed safely. We have treated 108 patients who had over 1500 ml of material removed. Eight-eight percent of the patients were female; 12 percent were male. Using the body-mass index, 3 percent of patients were underweight, 70 percent were normal weight, and 27 percent were overweight. Fifty-five patients (51 percent) had 1500 to 2499 ml of material removed, 26 patients (24 percent) had 2500 to 3499 ml removed, 16 patients (15 percent) had 3500 to 4499 ml removed, and 11 patients (10 percent) had over 4500 ml removed. All patients were treated in the hospital; 44 percent were admitted after surgery. A total of 227 units of autologous and 2 units of homologous blood were transfused. As measured by a computerized monitor, the average amount of blood in the material removed from thighs was 30 percent; from abdomens, the blood loss was 45 percent. The aesthetic results were generally excellent. No complications were encountered. A few patients developed undesired sequelae, the most common of which was seroma formation, which occurred in 19 percent of those who had suction of abdominal-wall fat. We believe that large-volume suction lipectomy is safe and efficacious, provided attention is directed to such important aspects of patient care as anesthesia, fluid replacement, and blood loss.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tumescent Technique for Local Anesthesia Improves Safety in Large-Volume Liposuction
Klein, J. A. (1993) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199311000-00014 · Cited by 475
Training the Generation X Plastic Surgeon: Dispelling the Myths?
Rohrich, R. J. (2001) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-200111000-00048 · Cited by 277
Safety of Tumescent Liposuction in 15,336 Patients: National Survey Results
HANKE, W. C., BERNSTEIN, G., & BULLOCK, S. (1995) · Dermatologic Surgery · doi:10.1111/j.1524-4725.1995.tb00213.x · Cited by 269
A Classification of Facial Wrinkles
Lemperle, G., Holmes, R. E., Cohen, S. R., & Lemperle, S. M. (2001) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-200111000-00050 · Cited by 184
Safety Considerations and Fluid Resuscitation in Liposuction: An Analysis of 53 Consecutive Patients
Trott, S. A., Beran, S. J., Rohrich, R. J., Kenkel, J. M., Adams, W. P., & Klein, K. W. (1998) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199811000-00063 · Cited by 141
Metadata
- Authors
- Courtiss, E. H., Choucair, R. J., & Donelan, M. B.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 1992-06
- Volume
- 89
- Issue
- 6
- Pages
- 1068-1079
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W2086587391
- Cited by
- 91
- References
- 0
- FWCI
- 4.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Large-Volume Suction Lipectomy: An Analysis of 108 Patients. https://app.cochat.ai/papers/10.1097/00006534-199206000-00012
- The paper
- Courtiss, E. H., Choucair, R. J., & Donelan, M. B. (1992). Large-Volume Suction Lipectomy: An Analysis of 108 Patients. Plastic and Reconstructive Surgery. https://doi.org/10.1097/00006534-199206000-00012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.