Human Pressure Perception Values for Constant and Moving One- and Two-Point Discrimination
Abstract
Despite the need to evaluate sensibility for accurate diagnosis and the need to record the degree of sensation achieved in the postoperative period, the clinician has been without the ability to measure human pressure perception accurately. Traditionally, the Semmes-Weinstein monofilaments were used to measure the static one-point discrimination threshold. A new sensory testing instrument, the Pressure-Specifying Sensory Device, was used to obtain normative data from the index and little finger of the dominant hand in 35 people ranging in age from 16 to 83 with no known neurologic impairment. Pressure perceptions for static one- and two-point discrimination (s1PD, s2PD) and moving one- and two-point discrimination (m1PD, m2PD) were recorded. The mean values (+/- SD) were 0.13 +/- 0.06, 0.24 +/- 0.12, 0.22 +/- 0.10, and 0.26 +/- 0.13 gm/mm2 for s1PD, s2PD, m1PD, and m2PD, respectively, on the index finger and 0.07 +/- 0.05, 0.16 +/- 0.12, 0.17 +/- 0.07, and 0.21 +/- 0.14 gm/mm2 for s1PD, s2PD, m1PD, and m2PD, respectively, for the little finger. The little finger was significantly more sensitive than the index finger (p less than 0.001). There was no significant change in pressure perception with increasing age.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
A flexible and highly sensitive strain-gauge sensor using reversible interlocking of nanofibres
Pang, C., Lee, G.-Y., Kim, T.-I., Kim, S. M., Kim, H. N., Ahn, S.-H., & Suh, K.-Y. (2012) · Nature Materials · doi:10.1038/nmat3380 · Cited by 1,695
Sun, J., Keplinger, C., Whitesides, G. M., & Suo, Z. (2014) · Advanced Materials · doi:10.1002/adma.201403441 · Cited by 1,198
Pyo, S., Lee, J., Bae, K., Sim, S., & Kim, J. (2021) · Advanced Materials · doi:10.1002/adma.202005902 · Cited by 631
Metadata
- Authors
- Dellon, E. S., Mourey, R., Dellon, A. L., & Dellon, A. L.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 1992-07
- Volume
- 90
- Issue
- 1
- Pages
- 112-117
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W1978123413
- Cited by
- 187
- References
- 0
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Human Pressure Perception Values for Constant and Moving One- and Two-Point Discrimination. https://app.cochat.ai/papers/10.1097/00006534-199207000-00017
- The paper
- Dellon, E. S., Mourey, R., Dellon, A. L., & Dellon, A. L. (1992). Human Pressure Perception Values for Constant and Moving One- and Two-Point Discrimination. Plastic and Reconstructive Surgery. https://doi.org/10.1097/00006534-199207000-00017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.