The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Radial Forearm Flap Donor-Site Complications and Morbidity: A Prospective Study
Abstract
One-hundred patients undergoing radial forearm flap reconstruction in the head and neck over a 2-year period were followed prospectively to assess complications and morbidity associated with the radial flap donor site. Eighty-six patients were available follow-up at 3 months and 74 at 1 year (49 fasciocutaneous, 25 composite). Partial loss of the donor-site skin graft occurred in 14 patients (16 percent), with exposure of tendons in 11 patients (13 percent). Delay in healing of the split-thickness skin graft at the donor site occurred in 19 patients (22 percent). Fracture of the radius occurred in 6 of 35 patients with composite flaps (17 percent). Superficial radial nerve sensation was reduced in 24 patients (32 percent) at 1 year. Ten patients (14 percent) reported cold intolerance, and 21 patients (28 percent) complained of poor aesthetic result. Function of the donor arm was restricted in 8 patients (16 percent) in the fasciocutaneous group, in 7 patients (36 percent) in the composite group without fracture, and in all patients who had a fracture of the radius following harvesting of composite flaps. Detailed measurements of forearm circumference, grip strength, pinch strength, and wrist movements showed greater reduction in these parameters in patients reporting restricted function compared with those reporting normal function. It is concluded that there is a low incidence of long-term morbidity associated with fasciocutaneous flaps and a higher incidence with composite flaps. Fracture of the radius results in reduced function in all cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reducing Morbidity in the Radial Forearm Flap Donor Site
Bardsley, A. F., Soutar, D. S., Elliot, D., & Batchelor, A. G. (1990) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199008000-00014 · Cited by 290
The Radial Forearm Flap Donor Site
Meland, N. B., Core, G. B., & Hoverman, V. R. (1993) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199304001-00019 · Cited by 53
Cited by
Radial Artery Cannulation: A Comprehensive Review of Recent Anatomic and Physiologic Investigations
Brzezinski, M., Luisetti, T., & London, M. J. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181bbd416 · Cited by 354
Anterolateral Thigh Flap Donor-Site Complications and Morbidity
Kimata, Y., Uchiyama, K., Ebihara, S., Sakuraba, M., Iida, H., Nakatsuka, T., & Harii, K. (2000) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-200009010-00009 · Cited by 327
Metadata
- Authors
- Richardson, D., Fisher, S. E., Vaughan, D. E., & Brown, J. S.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 1997-01
- Volume
- 99
- Issue
- 1
- Pages
- 109-115
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W2046597680
- Cited by
- 360
- References
- 2
- FWCI
- 7.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radial Forearm Flap Donor-Site Complications and Morbidity: A Prospective Study. https://app.cochat.ai/papers/10.1097/00006534-199701000-00017
- The paper
- Richardson, D., Fisher, S. E., Vaughan, D. E., & Brown, J. S. (1997). Radial Forearm Flap Donor-Site Complications and Morbidity: A Prospective Study. Plastic and Reconstructive Surgery. https://doi.org/10.1097/00006534-199701000-00017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.