Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 360

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Radial Forearm Flap Donor-Site Complications and Morbidity: A Prospective Study

Richardson, David, Fisher, Sheila E., Vaughan, David E., Brown, James S.·1997·Plastic and Reconstructive Surgery

Abstract

One-hundred patients undergoing radial forearm flap reconstruction in the head and neck over a 2-year period were followed prospectively to assess complications and morbidity associated with the radial flap donor site. Eighty-six patients were available follow-up at 3 months and 74 at 1 year (49 fasciocutaneous, 25 composite). Partial loss of the donor-site skin graft occurred in 14 patients (16 percent), with exposure of tendons in 11 patients (13 percent). Delay in healing of the split-thickness skin graft at the donor site occurred in 19 patients (22 percent). Fracture of the radius occurred in 6 of 35 patients with composite flaps (17 percent). Superficial radial nerve sensation was reduced in 24 patients (32 percent) at 1 year. Ten patients (14 percent) reported cold intolerance, and 21 patients (28 percent) complained of poor aesthetic result. Function of the donor arm was restricted in 8 patients (16 percent) in the fasciocutaneous group, in 7 patients (36 percent) in the composite group without fracture, and in all patients who had a fracture of the radius following harvesting of composite flaps. Detailed measurements of forearm circumference, grip strength, pinch strength, and wrist movements showed greater reduction in these parameters in patients reporting restricted function compared with those reporting normal function. It is concluded that there is a low incidence of long-term morbidity associated with fasciocutaneous flaps and a higher incidence with composite flaps. Fracture of the radius results in reduced function in all cases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00006534-199701000-00017

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 360

Metadata

Authors
Richardson, D., Fisher, S. E., Vaughan, D. E., & Brown, J. S.
Venue
Plastic and Reconstructive Surgery
Published
1997-01
Volume
99
Issue
1
Pages
109-115
ISSN
0032-1052 (ISSN-L)
OpenAlex
W2046597680
Cited by
360
References
2
FWCI
7.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Radial Forearm Flap Donor-Site Complications and Morbidity: A Prospective Study. https://app.cochat.ai/papers/10.1097/00006534-199701000-00017
The paper
Richardson, D., Fisher, S. E., Vaughan, D. E., & Brown, J. S. (1997). Radial Forearm Flap Donor-Site Complications and Morbidity: A Prospective Study. Plastic and Reconstructive Surgery. https://doi.org/10.1097/00006534-199701000-00017

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.