Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 238

The DOI matches its Crossref record.

Le Fort III Advancement with Gradual Distraction Using Internal Devices

Chin, Martin, Toth, Bryant A. · 1997 · Plastic & Reconstructive Surgery

Abstract

The purpose of this report is to demonstrate a practical clinical method for advancement of the midface using a combination of Le Fort III osteotomy and gradual distraction. Use of internal, submergible distraction devices and modification of the Ilizarov distraction protocol are presented. Case reports show the effect of departing from the Ilizarov protocol by eliminating the latency period, initiating distraction intraoperatively, and rapidly distracting the segments postoperatively. A method of controlling fragment distraction rate by regulating pressures within the osteotomy site is described. The design and surgical application of internal distraction devices are shown. Nine patients with midface hypoplasia related to craniofacial anomalies underwent Le Fort III osteotomies assisted by gradual distraction. Ages ranged from 4 to 13 years. Custom internal distraction devices were employed to meet the unique requirements of each patient. Activation of the distraction device was accomplished by a percutaneous pin that remained in place for 3 to 5 days. The rate of transport was determined by regulating the forces within the distraction site. The internal devices remained in place for 6 months for fixation of the transported fragment. Midface advancement, measured as the anterior displacement of the infraorbital rim, ranged from 16 to 30 mm, with a mean of 20 mm. The typical force required to produce incremental movement of the Le Fort III osteotomy was found to be between 7 and 9 kg as transport exceeded 10 mm. Four patients with obstructive sleep apnea prior to surgery had resolution of the disorder. All the midface advancements remained clinically stable. Establishment of osseous continuity was verified by surgical examination in the four patients in whom the distraction devices have been removed. Combining intraoperative advancement of the Le Fort III osteotomy with gradual distraction consistently resulted in larger movements than could be achieved with conventional osteotomies and rigid fixation alone. The pediatric craniofacial skeleton responds differently to distraction than does the orthopedic skeleton. Eliminating the latency period, establishing a substantial bone gap intraoperatively, and rapidly distracting the fragment postoperatively did not adversely affect the osseous union in these patients. The internal, submergible feature of the device design offers advantages in patient acceptance, fixation stability, and wound management. This method of Le Fort III midface advancement has been shown to be clinically practical and effective.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00006534-199709001-00001

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 238

Metadata

Authors
Chin, M., & Toth, B. A.
Venue
Plastic & Reconstructive Surgery
Published
1997-09
Volume
100
Issue
Supplement 1
Pages
819-830
ISSN
0032-1052 (ISSN-L)
OpenAlex
W2012294771
Cited by
238
References
0
FWCI
29.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Le Fort III Advancement with Gradual Distraction Using Internal Devices. https://app.cochat.ai/papers/10.1097/00006534-199709001-00001
The paper
Chin, M., & Toth, B. A. (1997). Le Fort III Advancement with Gradual Distraction Using Internal Devices. Plastic & Reconstructive Surgery. https://doi.org/10.1097/00006534-199709001-00001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.