The DOI matches its Crossref record.
Use of Octyl-2-Cyanoacrylate for Skin Closure in Facial Plastic Surgery
Abstract
Octyl-2-cyanoacrylate is a long carbon chain cyanoacrylate derivative that is stronger and more pliable than its shorter chain derivatives. One hundred and eleven patients underwent elective surgical procedures by the same surgeon using either octyl-2-cyanoacrylate or sutures for skin closure at the University of Illinois at Chicago. Most patients underwent excision of benign skin lesions with a mean wound size of 112 mm3. Patients were randomized into either control (vertical mattress suture closure) or test groups (closure with octyl-2-cyanoacrylate). Surgical judgment was used to determine which wounds in each group required application of subcutaneous sutures to relieve tension and aid in skin edge eversion. Generally, full-thickness (through dermis) wounds larger than 1 cm3 required the use of subcutaneous sutures. The time required to close the epidermis with suture (mean, 3 minutes and 47 seconds) was about four times that of octyl-2-cyanoacrylate (mean, 55 seconds). Wounds were evaluated at 5 to 7 days for infection, wound dehiscence, or tissue reaction, and at 90 days using the modified Hollander wound evaluation scale. At 1 year, photographs of the wounds were evaluated by two facial plastic surgeons that graded the cosmetic outcome using a previously validated visual analog scale. There were no instances of wound dehiscence, hematoma, or infection in either group. Results of wound evaluation at 90 days determined by the modified Hollander scal revealed equivalent cosmetic results in both groups. Results of the visual analog scale ratings showed scores of 21.7 +/- 16.3 for the 49 patients treated with octyl-2-cyanoacrylate and 29.2 +/- 17.7 for the 51 control patients treated with sutures. The lower visual analog scale score represented a superior cosmetic outcome at 1 year with the octyl-2-cyanoacrylate as compared with sutures. This difference is statistically significant at p = 0.03. Additionally, patient satisfaction was very high in the group treated with octyl-2-cyanoacrylate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A prospectus on tissue adhesives
Reece, T. B., Maxey, T. S., & Kron, I. L. (2001) · The American Journal of Surgery · doi:10.1016/s0002-9610(01)00742-5 · Cited by 284
Tissue adhesives for closure of surgical incisions
Dumville, J. C., Coulthard, P., Worthington, H. V., Riley, P., Patel, N., Darcey, J., Esposito, M., van der Elst, M., & van Waes, O. J. F. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004287.pub4 · Cited by 257
Tissue adhesives: From research to clinical translation
Bal-Ozturk, A., Cecen, B., Avci-Adali, M., Topkaya, S. N., Alarcin, E., Yasayan, G., Li, Y.-C. E., Bulkurcuoglu, B., Akpek, A., Avci, H., et al. (2021) · Nano Today · doi:10.1016/j.nantod.2020.101049 · Cited by 246
Dopa-empowered schiff base forming alginate hydrogel glue for rapid hemostatic control
Song, C. K., Kim, M.-K., Lee, J., Davaa, E., Baskaran, R., & Yang, S.-G. (2019) · Macromolecular Research · doi:10.1007/s13233-019-7026-3 · Cited by 46
Metadata
- Authors
- Toriumi, D. M., OʼGrady, K., Desai, D., & Bagal, A.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 1998-11
- Volume
- 102
- Issue
- 6
- Pages
- 2209-2219
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W2064156186
- Cited by
- 283
- References
- 0
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of Octyl-2-Cyanoacrylate for Skin Closure in Facial Plastic Surgery. https://app.cochat.ai/papers/10.1097/00006534-199811000-00062
- The paper
- Toriumi, D. M., OʼGrady, K., Desai, D., & Bagal, A. (1998). Use of Octyl-2-Cyanoacrylate for Skin Closure in Facial Plastic Surgery. Plastic and Reconstructive Surgery. https://doi.org/10.1097/00006534-199811000-00062
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.