The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Venous Congestion and Blood Flow in Free Transverse Rectus Abdominis Myocutaneous and Deep Inferior Epigastric Perforator Flaps
Abstract
A series of 240 deep inferior epigastric perforator (DIEP) flaps and 271 free transverse rectus abdominis myocutaneous (TRAM) flaps from two institutions was reviewed to determine the incidence of diffuse venous insufficiency that threatened flap survival and required a microvascular anastomosis to drain the superficial inferior epigastric vein. This problem occurred in five DIEP flaps and did not occur in any of the free TRAM flaps. In each of these cases, the presence of a superficial inferior epigastric vein that was larger than usual was noted. It is therefore suggested that if an unusually large superficial inferior epigastric vein is noted when a DIEP flap is elevated, the vein should be preserved for possible use in flap salvage. Anatomical studies with Microfil injections of the superficial venous system of the DIEP or TRAM flap were also performed in 15 cadaver and 3 abdominoplasty specimens to help determine why venous circulation (and flap survival) in zone IV of the flaps is so variable. Large lateral branches crossing the midline were found in only 18 percent of cases, whereas 45 percent had indirect connections through a deeper network of smaller veins and 36 percent had no demonstrable crossing branches at all. This absence of crossing branches in many patients may explain why survival of the zone IV portion of such flaps is so variable and unpredictable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The donor site morbidity of free DIEP flaps and free TRAM flaps for breast reconstruction
Blondeel, P. N., Vanderstraeten, G. G., Monstrey, S. J., Van Landuyt, K., Tonnard, P., Lysens, R., Boeckx, W. D., & Matton, G. (1997) · British Journal of Plastic Surgery · doi:10.1016/s0007-1226(97)90540-3 · Cited by 624
Self-citation
Cited by
A 10-Year Retrospective Review of 758 DIEP Flaps for Breast Reconstruction
Gill, P. S., Hunt, J. P., Guerra, A. B., Dellacroce, F. J., Sullivan, S. K., Boraski, J., Metzinger, S. E., Dupin, C. L., & Allen, R. J. (2004) · Plastic and Reconstructive Surgery · doi:10.1097/01.prs.0000110328.47206.50 · Cited by 605
Yueh, J. H., Slavin, S. A., Adesiyun, T., Nyame, T. T., Gautam, S., Morris, D. J., Tobias, A. M., & Lee, B. T. (2010) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0b013e3181cb6351 · Cited by 390
DIEP and Pedicled TRAM Flaps: A Comparison of Outcomes
Garvey, P. B., Buchel, E. W., Pockaj, B. A., Casey, W. J., Gray, R. J., Hern??ndez, J. L., & Samson, T. D. (2006) · Plastic and Reconstructive Surgery · doi:10.1097/01.prs.0000210679.77449.7d · Cited by 255
Metadata
- Authors
- Blondeel, P. N., Arnstein, M., Verstraete, K., Depuydt, K., Van Landuyt, K. H., Monstrey, S. J., & Kroll, S. S.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 2000-11
- Volume
- 106
- Issue
- 6
- Pages
- 1295-1299
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W2055525814
- Cited by
- 334
- References
- 1
- FWCI
- 7.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Venous Congestion and Blood Flow in Free Transverse Rectus Abdominis Myocutaneous and Deep Inferior Epigastric Perforator Flaps. https://app.cochat.ai/papers/10.1097/00006534-200011000-00009
- The paper
- Blondeel, P. N., Arnstein, M., Verstraete, K., Depuydt, K., Van Landuyt, K. H., Monstrey, S. J., & Kroll, S. S. (2000). Venous Congestion and Blood Flow in Free Transverse Rectus Abdominis Myocutaneous and Deep Inferior Epigastric Perforator Flaps. Plastic and Reconstructive Surgery. https://doi.org/10.1097/00006534-200011000-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.