The DOI matches its Crossref record.
A 1-Year Study of Osteoinduction in Hydroxyapatite-Derived Biomaterials in an Adult Sheep Model: Part I
Abstract
The study presented here investigated hydroxyapatite biomaterials implanted in soft-tissue sites in adult sheep to determine whether these materials are osteoinductive and whether the rate of osteoinduction can be increased by manipulating the composition and porosity of the implants. For the study, 16.8-mm x 5-mm discs were prepared from mixtures of hydroxyapatite and beta-tricalcium phosphate. Five mixtures of hydroxyapatite-ceramic and hydroxyapatite-cement paste forms were studied: 100 percent hydroxyapatite-ceramic (Interpore), 60 percent hydroxyapatite-ceramic, 100 percent hydroxyapatite-cement paste, 60 percent hydroxyapatite-cement paste, and 20 percent hydroxyapatite-cement paste. Biomaterials were implanted in subcutaneous and intramuscular soft-tissue pockets in 10 adult sheep. Cranial bone grafts of equal dimension were implanted as controls. One year after implantation, the volume of all biomaterials and bone grafts was determined from a computed tomographic scan, and porosity and bone formation were determined using backscatter electron microscopy. Cranial bone and the 20 percent hydroxyapatite-cement paste implants demonstrated significant volume reduction in all sites after 1 year (p < 0.001). No significant difference in volume of the remaining four biomaterials was found. There was no significant change in pore size in the ceramic implants (range, 200 to 300 micro) and in the cement-paste implants containing 60 percent hydroxyapatite or more (range, 3 to 5 nm). Pore size in the cement-paste implants containing 20 percent hydroxyapatite increased significantly with resorption of the tricalcium-phosphate component, reaching a maximum of 200 to 300 micro in the periphery, where the greatest tricalcium-phosphate resorption had occurred. Both ceramic biomaterials demonstrated lamellar bone deposition within well-formed haversian systems through the entire depth of the implants, ranging from a mean of 6.6 percent to 11.7 percent. There was minimal bone formation in the cement-paste implants containing 60 percent hydroxyapatite or more. In contrast, cement-paste implants containing 20 percent hydroxyapatite demonstrated up to 10 percent bone replacement, which was greatest in the periphery of the implants where the greatest tricalcium-phosphate resorption had occurred. This study confirms the occurrence of true osteoinduction within hydroxyapatite-derived biomaterials, when examined using backscatter techniques. In this study, the rate of osteoinduction was greatest when a porous architecture was maintained, which was best achieved in ceramic rather than cement-paste forms of hydroxyapatite. Porosity and resultant bone formation in cement-paste implants can be improved by combining hydroxyapatite with a rapidly resorbing component, such as tricalcium phosphate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bone Tissue Engineering: Recent Advances and Challenges
Amini, A. R., Laurencin, C. T., & Nukavarapu, S. P. (2012) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v40.i5.10 · Cited by 2,336
Calcium Phosphate-Based Osteoinductive Materials
LeGeros, R. Z. (2008) · Chemical Reviews · doi:10.1021/cr800427g · Cited by 1,321
Calcium phosphates in biomedical applications: materials for the future?
Habraken, W., Habibovic, P., Epple, M., & Bohner, M. (2016) · Materials Today · doi:10.1016/j.mattod.2015.10.008 · Cited by 857
Osteoinductive ceramics as a synthetic alternative to autologous bone grafting
Yuan, H., Fernandes, H., Habibovic, P., de Boer, J., Barradas, A. M. C., de Ruiter, A., Walsh, W. R., van Blitterswijk, C. A., & de Bruijn, J. D. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1003600107 · Cited by 746
Chitosan-based scaffolds for bone tissue engineering
Levengood, S. K. L., & Zhang, M. (2014) · Journal of Materials Chemistry B · doi:10.1039/c4tb00027g · Cited by 672
Metadata
- Authors
- Gosain, A. K., Song, L., Riordan, P., Amarante, M. T., Nagy, P. G., Wilson, C. R., Toth, J. M., & Ricci, J. L.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 2002-02
- Volume
- 109
- Issue
- 2
- Pages
- 619-630
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W1977273370
- Cited by
- 186
- References
- 0
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A 1-Year Study of Osteoinduction in Hydroxyapatite-Derived Biomaterials in an Adult Sheep Model: Part I. https://app.cochat.ai/papers/10.1097/00006534-200202000-00032
- The paper
- Gosain, A. K., Song, L., Riordan, P., Amarante, M. T., Nagy, P. G., Wilson, C. R., Toth, J. M., & Ricci, J. L. (2002). A 1-Year Study of Osteoinduction in Hydroxyapatite-Derived Biomaterials in an Adult Sheep Model: Part I. Plastic and Reconstructive Surgery. https://doi.org/10.1097/00006534-200202000-00032
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.