Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 215

The DOI matches its Crossref record.

CYSTOID MACULAR DEGENERATION IN CHRONIC CENTRAL SEROUS CHORIORETINOPATHY

IIDA, TOMOHIRO, YANNUZZI, LAWRENCE A., SPAIDE, RICHARD F., BORODOKER, NATALIE, CARVALHO, CYNTHIA A., NEGRÃO, SILVANA · 2003 · RETINA

Abstract

PURPOSE: To describe the optical coherence tomography (OCT) and fluorescein angiography findings in the macula of eyes with chronic central serous chorioretinopathy (CSC) and reduced central vision. METHODS: Using OCT, clinical examination, and fluorescein and indocyanine green (ICG) angiography, the authors examined eight eyes of seven patients with CSC, an attached macula, and reduced central vision of 20/200 or worse. All had a history of chronic CSC with resolution of the subretinal fluid in the macular area and poor vision. RESULTS: Patient ages ranged from 55 to 82 years (mean, 66 years). All eight eyes had some parafoveal, patchy RPE atrophy with corresponding transmission hyperfluorescence (window defect) on fluorescein angiography. Five eyes also had a window defect in the foveal area. With OCT, the foveal area revealed variable areas of cystoid change and atrophy in seven of the eight eyes. In four of these eyes, the cystoid changes were not seen on clinical examination or fluorescein angiography. The seven eyes with cystoid changes imaged with OCT had no intraretinal leakage of fluorescein in the foveal region. The authors categorized these eyes as having cystoid macular degeneration (CMD). One other eye had foveal thinning or atrophy without cystoid changes. CONCLUSIONS: Intraretinal cystoid spaces without intraretinal leakage, or CMD, was a common finding in eyes with chronic CSC and reduced central vision after resolution of subretinal fluid. OCT was useful to establish the presence of CMD and foveal atrophy, even when these changes were not clearly evident on clinical examination or fluorescein angiography. Chronic foveal detachment and antecedent intraretinal leakage were proposed to be the mechanisms for the development of the changes. CMD in conjunction with foveal atrophy was an important clinical finding to account for the poor visual outcome in patients with CSC.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00006982-200302000-00001

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 215

Metadata

Authors
IIDA, T., YANNUZZI, L. A., SPAIDE, R. F., BORODOKER, N., CARVALHO, C. A., & NEGRÃO, S.
Venue
RETINA
Published
2003-02
Volume
23
Issue
1
Pages
1-7
ISSN
0275-004X (ISSN-L)
OpenAlex
W2017615316
Cited by
215
References
0
FWCI
7.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: CYSTOID MACULAR DEGENERATION IN CHRONIC CENTRAL SEROUS CHORIORETINOPATHY. https://app.cochat.ai/papers/10.1097/00006982-200302000-00001
The paper
IIDA, T., YANNUZZI, L. A., SPAIDE, R. F., BORODOKER, N., CARVALHO, C. A., & NEGRÃO, S. (2003). CYSTOID MACULAR DEGENERATION IN CHRONIC CENTRAL SEROUS CHORIORETINOPATHY. RETINA. https://doi.org/10.1097/00006982-200302000-00001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.