The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
SEMIAUTOMATED PATTERNED SCANNING LASER FOR RETINAL PHOTOCOAGULATION
Abstract
In Brief Sequential application of a large number of single spots in retinal photocoagulation often results in significant physician fatigue and patient discomfort. This article describes a semiautomated scanning laser retinal photocoagulator that greatly improves efficiency and increases the precision by rapid application of patterns of lesions using laser pulses as short as 10 milliseconds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Treatment Techniques and Clinical Guidelines for Photocoagulation of Diabetic Macular Edema
(1987) · Ophthalmology · doi:10.1016/s0161-6420(87)33527-4 · Cited by 544
Metadata
- Authors
- BLUMENKRANZ, M. S., YELLACHICH, D., ANDERSEN, D. E., WILTBERGER, M. W., MORDAUNT, D., MARCELLINO, G. R., & PALANKER, D.
- Venue
- Retina
- Published
- 2006-03
- Volume
- 26
- Issue
- 3
- Pages
- 370-376
- ISSN
- 0275-004X (ISSN-L)
- OpenAlex
- W1978870219
- Cited by
- 243
- References
- 1
- FWCI
- 4.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SEMIAUTOMATED PATTERNED SCANNING LASER FOR RETINAL PHOTOCOAGULATION. https://app.cochat.ai/papers/10.1097/00006982-200603000-00024
- The paper
- BLUMENKRANZ, M. S., YELLACHICH, D., ANDERSEN, D. E., WILTBERGER, M. W., MORDAUNT, D., MARCELLINO, G. R., & PALANKER, D. (2006). SEMIAUTOMATED PATTERNED SCANNING LASER FOR RETINAL PHOTOCOAGULATION. Retina. https://doi.org/10.1097/00006982-200603000-00024
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.