The DOI matches its Crossref record.
Progressive Isoinertial Lifting Evaluation: I. A Standardized Protocol and Normative Database
Abstract
Dynamic tests of trunk strength and lifting capacity have become more popular in recent years, offering certain advantages over static isometric tests in measuring patient progress in functional restoration programs for spinal disorders. However, equipment for performing such tests is expensive to buy, complex to run, and requires technical expertise and clinical volume unavailable in most physician offices. In this study, a new dynamic test known as Progressive Isoinertial Lifting Evaluation (PILE) is described, which draws upon prior psychophysical and isoinertial methods. An industrial sample of 61 male and 31 female incumbent workers were tested using the PILE, and a variety of anthropometric normalizing factors were evaluated. The isolation of an "Adjusted Weight" (AW) normalizing factor is documented, after which normative data are presented for male and female workers utilizing lumbar (0-30 inches) and cervical (30-54 inches) dynamic protocols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lindström, I., Öhlund, C., Eek, C., Wallin, L., Peterson, L.-E., Fordyce, W. E., & Nachemson, A. L. (1992) · Physical Therapy · doi:10.1093/ptj/72.4.279 · Cited by 530
Abenhaim, L., Rossignol, M., Valat, J., Nordin, M., Avouac, B., Blotman, F., Charlot, J., Dreiser, R. L., Legrand, E., Rozenberg, S., et al. (2000) · Spine · doi:10.1097/00007632-200002151-00001 · Cited by 378
Smeets, R., Köke, A., Lin, C., Ferreira, M., & Demoulin, C. (2011) · Arthritis Care & Research · doi:10.1002/acr.20542 · Cited by 262
E. M. H. Haldorsen, K. K. (1998) · Scandinavian Journal of Rheumatology · doi:10.1080/030097498441128 · Cited by 107
Long-term, non-specific spinal pain: reliable and valid subgroups of patients
Bergström, G., Bodin, L., Jensen, I. B., Linton, S. J., & Nygren, Å. L. (2001) · Behaviour Research and Therapy · doi:10.1016/s0005-7967(99)00175-8 · Cited by 69
Metadata
- Authors
- MAYER, T. G., BARNES, D., KISHINO, N. D., NICHOLS, G., GATCHEL, R. J., MAYER, H., & MOONEY, V.
- Venue
- Spine
- Published
- 1988-09
- Volume
- 13
- Issue
- 9
- Pages
- 993-997
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2047273545
- Cited by
- 219
- References
- 0
- FWCI
- 1.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Progressive Isoinertial Lifting Evaluation: I. A Standardized Protocol and Normative Database. https://app.cochat.ai/papers/10.1097/00007632-198809000-00005
- The paper
- MAYER, T. G., BARNES, D., KISHINO, N. D., NICHOLS, G., GATCHEL, R. J., MAYER, H., & MOONEY, V. (1988). Progressive Isoinertial Lifting Evaluation: I. A Standardized Protocol and Normative Database. Spine. https://doi.org/10.1097/00007632-198809000-00005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.