Progressive Isoinertial Lifting Evaluation: II. A Comparison with Isokinetic Lifting in a Disabled Chronic Low-Back Pain Industrial Population
The DOI matches its Crossref record.
Abstract
The Progressive Isoinertial Lifting Evaluation (PILE), as described in Part I of this series of articles, is a simplified test combining psychophysical and isoinertial protocols to provide an unconstrained lifting assessment. In the second part of this study, 100 chronically disabled low-back pain patients (57 men and 43 women) were studied at two points: 1) at initial evaluation, when referred for possible entry into a comprehensive Functional Restoration treatment program; and 2) at the conclusion of the treatment (an average 7 weeks later). Results of simultaneous lumbar PILE and Cybex Liftask (Lumex, Ronkonkoma, NY) tests are presented, showing that patients may frequently double or triple initial lifting capacity after undergoing the functional restoration training program, achieving lifting levels at or above normal for incumbent industrial workers. Overall, results demonstrate that the PILE test can be an effective baseline screening test for lifting capacity under certain circumstances. Although several drawbacks affecting the PILE as an isolated test are discussed, its usefulness as part of a battery of physical capacity tests making up a quantitative functional evaluation is clearly demonstrated. Finally, the potential use of PILE as a safe, inexpensive, simple, and relevant screening test for frequent lifting capacity in worker selection is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
On the reliability and validity of manual muscle testing: a literature review
Cuthbert, S. C., & Goodheart, G. J. (2007) · Chiropractic & Osteopathy · doi:10.1186/1746-1340-15-4 · Cited by 475
Smeets, R., Köke, A., Lin, C., Ferreira, M., & Demoulin, C. (2011) · Arthritis Care & Research · doi:10.1002/acr.20542 · Cited by 262
Course of low back pain among nurses: a longitudinal study across eight years
Maul, I., Läubli, T., Klipstein, A., & Krueger, H. (2003) · Occupational and Environmental Medicine · doi:10.1136/oem.60.7.497 · Cited by 236
Aggressive Exercise as Treatment for Chronic Low Back Pain
Cohen, I., & Rainville, J. (2002) · Sports Medicine · doi:10.2165/00007256-200232010-00004 · Cited by 58
Lindell, O., Johansson, S.-E., & Strender, L.-E. (2008) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-9-172 · Cited by 28
“Then the assistant carried out, among other tests, a lift test [36].”
Method
Metadata
- Authors
- MAYER, T. G., BARNES, D., NICHOLS, G., KISHINO, N. D., COVAL, K., PIEL, B., HOSHINO, D., & GATCHEL, R. J.
- Venue
- Spine
- Published
- 1988-09
- Volume
- 13
- Issue
- 9
- Pages
- 998-1002
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W1985851191
- Cited by
- 149
- References
- 0
- FWCI
- 1.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Progressive Isoinertial Lifting Evaluation: II. A Comparison with Isokinetic Lifting in a Disabled Chronic Low-Back Pain Industrial Population. https://app.cochat.ai/papers/10.1097/00007632-198809000-00006
- The paper
- MAYER, T. G., BARNES, D., NICHOLS, G., KISHINO, N. D., COVAL, K., PIEL, B., HOSHINO, D., & GATCHEL, R. J. (1988). Progressive Isoinertial Lifting Evaluation: II. A Comparison with Isokinetic Lifting in a Disabled Chronic Low-Back Pain Industrial Population. Spine. https://doi.org/10.1097/00007632-198809000-00006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.