Effects of Rigidity of an Internal Fixation Device A Comprehensive Biomechanical Investigation
The DOI matches its Crossref record.
Abstract
Internal fixation with instrumentation often accompanies surgical fusion to augment spinal stability, provide temporary fixation while the surgical fusion mass unites, and enhance postoperative mobilization of a patient. Some surgeons, however, feel that the existing plate-screw designs are too rigid and are the primary cause of “iatrogenic‘’ adverse effects clinically observed. A three-part study, involving in vitro experimental protocol, analytical finite-element-based models, and an in vivo canine investigation, was undertaken to study the role of decreasing rigidity of a device on the biomechanical response of the stabilized segments. Two alternatives—the use of one variable screw placement (Steffee plate [unilateral, 1VSP model]) as opposed to two VSP plates (bilateral, 2VSP model) and two VSP plates with polymer washers placed in between the integral nut and plate (2MVSP model)—were considered for achieving a reduction in the rigidity of the conventional VSP system. The load-displacement data obtained from the in vitro experiments and the stress distributions within the stabilized and intact models predicted by the finite-element models revealed that the unilateral VSP system is less rigid and is likely to reduce stress shielding of the vertebral bodies compared with the 2VSP model. The undesirable effects associated with the use of the 1 VSP plate system are the presence of coupled motions due to the inherent asymmetry and the likely inability to provide enough rigidity for decompression procedures requiring a complete excision of the disc. The use of two MVSP plates overcomes these deficiencies. The presence of polymer washers decreases the stress-shielding effects (by about 20%) compared with the 2VSP model immediately following surgery and by an additional 4% over a 30-day period due to the stress-relaxation phenomena associated with polymer washers. The in vivo canine investigation (Part III of the study), in which the quality of the bone within the stabilized segment in 2MVSP and 2VSP models was assessed at 6 months following surgery, revealed a similar trend. The use of polymer washers in the 2MVSP canine group increased bone growth around screws, and the bone porosity was reduced compared with the 2VSP model. Thus, it appears that the new concept of using viscoelastic washers can be to a patient's advantage to reduce the effects of a rigid device on the bone quality (eg, stress-induced osteopenia) until the surgical fusion mass unites.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Development of 3D Printed Biodegradable Mesh with Antimicrobial Properties for Pelvic Organ Prolapse
Ren, J., Murray, R., Wong, C. S., Qin, J., Chen, M., Totsika, M., Riddell, A. D., Warwick, A., Rukin, N., & Woodruff, M. A. (2022) · Polymers · doi:10.3390/polym14040763 · Cited by 42
Metadata
- Authors
- GOEL, V. K., LIM, T.-H., GWON, J., CHEN, J.-Y., WINTERBOTTOM, J. M., PARK, J. B., WEINSTEIN, J. N., & AHN, J.-Y.
- Venue
- Spine
- Published
- 1991-03
- Volume
- 16
- Issue
- Supplement
- Pages
- S155-S161
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2058985629
- Cited by
- 190
- References
- 0
- FWCI
- 3.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of Rigidity of an Internal Fixation Device A Comprehensive Biomechanical Investigation. https://app.cochat.ai/papers/10.1097/00007632-199103001-00023
- The paper
- GOEL, V. K., LIM, T.-H., GWON, J., CHEN, J.-Y., WINTERBOTTOM, J. M., PARK, J. B., WEINSTEIN, J. N., & AHN, J.-Y. (1991). Effects of Rigidity of an Internal Fixation Device A Comprehensive Biomechanical Investigation. Spine. https://doi.org/10.1097/00007632-199103001-00023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.