Reliability of Isokinetic Measurements of Trunk Muscle Performance
The DOI matches its Crossref record.
Abstract
The purpose of this investigation was to assess the reliability of isokinetic trunk muscle performance. Sixty-one volunteers participated (29 men, 32 women; age range, 20-60 years). All subjects were without low-back symptoms at the time of testing. All testing was performed with the subject initially standing, using speeds of 60, 120, and 180 degrees per second. Ten repetitions of flexion and extension were performed reciprocally at each speed, with a 3-minute rest period between speeds. Test-retest intervals were 1 and 3 weeks from the initial test. Peak torque-to-body-weight ratios, extension-to-flexion ratios, and average work per repetition were calculated for each speed for flexion and extension. Data were analyzed with analysis of variance, intraclass correlation coefficients, and Pearson correlation coefficients. Intraclass correlation coefficient values ranged from .74 to .88 for measurements derived from peak torque, and from .88-.93 for measurements derived from work (with the exception of .69 for men at 180 degrees/sec). Standard error of measurements ranged from 8 to 32 ft-lb, with a tendency to increase with increasing speeds. It was concluded that, when using this protocol, isokinetic measurements of muscle function offer the clinician sensitive and reliable measurements of trunk muscle performance and that incorporating increased practice with women and longer rest periods with men may further decrease error associated with these isokinetic trunk strength measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Core Stability and Its Relationship to Lower Extremity Function and Injury
Willson, J. D., Dougherty, C. P., Ireland, M. L., & Davis, I. M. (2005) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/00124635-200509000-00005 · Cited by 662
Effect of Core Strength on the Measure of Power in the Extremities
Shinkle, J., Nesser, T. W., Demchak, T. J., & McMannus, D. M. (2012) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e31822600e5 · Cited by 195
Minimum rest period for strength recovery during a common isokinetic testing protocol
PARCELL, A. C., SAWYER, R. D., TRICOLI, V. A., & CHINEVERE, T. D. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200206000-00018 · Cited by 160
“(13) 60, 120, 180 10 Ascending 3 min Peak torque Dudley et al.”
BackgroundKeller, A., Hellesnes, J., & Jens I. Brox, A. (2001) · Spine · doi:10.1097/00007632-200104010-00017 · Cited by 152
“Conflicting results have been found for the reliability of the isokinetic trunk extensor strength test.(13,14,26,33,39) A learning effect from Test 1 to Test 2 and low reliability at higher angular velocities have been reported.”
BackgroundMethodResultInfluentialBio-signal based elbow angle and torque simultaneous prediction during isokinetic contraction
Zhou, Y., Liu, J., Zeng, J., Li, K., & Liu, H. (2019) · Science China Technological Sciences · doi:10.1007/s11431-018-9354-5 · Cited by 30
Metadata
- Authors
- DELITTO, A., ROSE, S. J., CRANDELL, C. E., & STRUBE, M. J.
- Venue
- Spine
- Published
- 1991-07
- Volume
- 16
- Issue
- 7
- Pages
- 800-803
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2056815945
- Cited by
- 82
- References
- 0
- FWCI
- 0.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability of Isokinetic Measurements of Trunk Muscle Performance. https://app.cochat.ai/papers/10.1097/00007632-199107000-00019
- The paper
- DELITTO, A., ROSE, S. J., CRANDELL, C. E., & STRUBE, M. J. (1991). Reliability of Isokinetic Measurements of Trunk Muscle Performance. Spine. https://doi.org/10.1097/00007632-199107000-00019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.