Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 181

The DOI matches its Crossref record.

Evaluation of rhBMP-2 With an OPLA Carrier in a Canine Posterolateral (Transverse Process) Spinal Fusion Model

Open access
Sandhu, Harvinder S., Kanim, Linda E. A., Kabo, J. Michael, Toth, Jeffrey M., Zeegen, Erik N., Liu, David, Seeger, Leanne L., Dawson, Edgar G. · 1995 · Spine

Abstract

STUDY DESIGN: Posterolateral L4-L5 transverse process fusions were done on 14 adult beagles. Six were implanted with recombinant human bone morphogenetic protein-2 carried by open-cell polylactic acid polymer delivery vehicle. Six received autogenous iliac bone graft. Two received carrier alone. Eleven were killed 3 months after implantation. One in each group was maintained for 8 months. OBJECTIVES: To compare recombinant human bone morphogenetic protein-2 and open-cell polylactic acid polymer with autogenous iliac bone for inducing transverse process fusion in the canine by 3 months and to determine whether transverse process decortication and implantation of carrier alone causes spontaneous transverse process fusion in the canine. SUMMARY OF BACKGROUND DATA: Recombinant human bone morphogenetic proteins have healed segmental long bone defects in several models. They have induced interlaminar and facet fusions in canines. Interlaminar and facet fusions have occurred after sham decortications in canines. Recombinant human bone morphogenetic protein-2 has not been evaluated for transverse process fusion in canines. Transverse process fusion is a preferred clinical method for achieving posterior lumbar fusion. METHODS: Fusion sites were evaluated by serial computed tomography scans. After the dogs were killed, explanted spines were subjected to manual testing, mechanical testing, high resolution radiography, and histologic analysis. RESULTS: One hundred percent of recombinant human bone morphogenetic protein-2-implanted sites had solid transverse process fusion by 3 months according to all measures. No autografted sites were fused at this interval. Osseous bridging of posterolateral gutters occurred in the recombinant human bone morphogenetic protein-2-implanted sites after 2 months, the earliest radiographic measure. None of the carrier-only sites showed bone formation. CONCLUSIONS: Recombinant bone morphogenetic protein-2 carried by open-cell polyactic acid polymer is superior to autogenous iliac bone for producing radiographically and mechanically solid transverse process fusions in canines by 3 months. Spontaneous transverse process fusion does not occur in canines after decortication and open-cell polylactic acid polymer implantation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00007632-199512150-00008

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 181

Metadata

Authors
Sandhu, H. S., Kanim, L. E. A., Kabo, J. M., Toth, J. M., Zeegen, E. N., Liu, D., Seeger, L. L., & Dawson, E. G.
Venue
Spine
Published
1995-12
Volume
20
Issue
24
Pages
2669-2682
ISSN
0362-2436 (ISSN-L)
OpenAlex
W2051085471
Cited by
181
References
0
FWCI
5.43
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of rhBMP-2 With an OPLA Carrier in a Canine Posterolateral (Transverse Process) Spinal Fusion Model. https://app.cochat.ai/papers/10.1097/00007632-199512150-00008
The paper
Sandhu, H. S., Kanim, L. E. A., Kabo, J. M., Toth, J. M., Zeegen, E. N., Liu, D., Seeger, L. L., & Dawson, E. G. (1995). Evaluation of rhBMP-2 With an OPLA Carrier in a Canine Posterolateral (Transverse Process) Spinal Fusion Model. Spine. https://doi.org/10.1097/00007632-199512150-00008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.