Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 278

The DOI matches its Crossref record.

Experimental Spinal Fusion With Recombinant Human Bone Morphogenetic Protein-2

Schimandle, Jeffrey H., Boden, Scott D., Hutton, William C. · 1995 · Spine

Abstract

Study Design. Lumbar intertransverse process arthrodesis using recombinant human bone morphogenetic protein-2 was performed in a previously established rabbit model for posterolateral spinal fusion and compared with fusions achieved using autogenous bone graft. Objectives. To qualitatively compare different recombinant human bone morphogenetic protein-2 dosages and carriers and to determine the efficacy of recombinant human bone morphogenetic protein-2 as a bone graft substitute to produce lumbar intertransverse process fusion in a validated rabbit model for posterolateral spinal fusion. Summary of Background Data. Autogenous bone was considered the most successful bone graft material used for spinal arthrodesis. Problems with its use may occur in 25-30% of patients and prompted the search for and investigation of bone graft substitutes and osteoinductive growth factors, such as bone morphogenetic proteins. Recombinant human bone morphogenetic protein-2 was used successfully in orthotopic sites to generate bone in animal mandibular and long bone defect models. Methods. Posterolateral intertransverse process arthrodeses were performed at L5-L6 in 56 rabbits using recombinant human bone morphogenetic protein-2 or autogenous bone graft. Rabbits were killed either 5 weeks later to qualitatively compare fusions achieved using different recombinant human bone morphogenetic protein-2 dosages and carriers or 4 weeks later to compare the efficacy of recombinant human bone morphogenetic protein-2 in achieving spinal fusion compared with using autogenous bone graft. Inspection, manual palpation, radiography, histology, and biomechanic testing were used to assess the fusion. Results. All rabbits implanted with recombinant human bone morphogenetic protein-2 achieved solid spinal fusion by manual palpation and were fused radiographically, whereas only 42% of the autograft control fusions were solid. More mature fusions with greater trabecular bone formation were shown radiographically and histologically in rabbits implanted with the highdose recombinant human bone morphogenetic protein-2 than with the low-dose recombinant human bone morphogenetic protein-2. Fusions achieved using recombinant human bone morphogenetic protein-2 delivered in the collagen carrier were more remodeled and homogeneous compared with using recombinant human bone morphogenetic protein-2 delivered in autograft ± collagen carrier. Fusions achieved with recombinant human bone morphogenetic protein-2 were biomechanically stronger and stiffer than fusions achieved using autogenous bone graft. Conclusions. Recombinant human bone morphogenetic protein-2 successfully and reliably achieved lumbar intertransverse process fusion in a validated rabbit model for posterolateral spinal fusion. Radiographically and histologically, greater and more rapid bone formation, consolidation, and remodeling were shown with recombinant human bone morphogenetic protein-2 compared with autogenous bone graft. Fusions achieved with recombinant human bone morphogenetic protein-2 were biomechanically stronger and stiffer than autograft fusions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00007632-199520120-00002

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 278

Metadata

Authors
Schimandle, J. H., Boden, S. D., & Hutton, W. C.
Venue
Spine
Published
1995-06
Volume
20
Issue
12
Pages
1326-1337
ISSN
0362-2436 (ISSN-L)
OpenAlex
W4243026607
Cited by
278
References
0
FWCI
7.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Experimental Spinal Fusion With Recombinant Human Bone Morphogenetic Protein-2. https://app.cochat.ai/papers/10.1097/00007632-199520120-00002
The paper
Schimandle, J. H., Boden, S. D., & Hutton, W. C. (1995). Experimental Spinal Fusion With Recombinant Human Bone Morphogenetic Protein-2. Spine. https://doi.org/10.1097/00007632-199520120-00002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.