The DOI matches its Crossref record.
Threaded Titanium Cages for Lumbar Interbody Fusions
Abstract
STUDY DESIGN: This study evaluated safety, fusion success rate, and clinical outcome of a new lumbar interbody hollow, threaded titanium fusion cage in a multicenter, prospective 236-case program adhering to a United States Food and Drug Administration Investigational Device Exemption controlled protocol. OBJECTIVES: The results were evaluated to demonstrate the safety and effectiveness of this new method to achieve solid lumbar interbody fusions. SUMMARY OF BACKGROUND DATA: Interbody fusions have certain distinct mechanical advantages over lateral or posterolateral ones. Autologous, cancellous bone is the preferred graft material, but is too soft to maintain the space during fusion without mechanical support. Various methods have been used in the past to maintain the graft integrity during fusion development. METHODS: An initial pilot study began on 10 patients (followed for 84 months, average 80 months). Two years after that investigation started, the multicenter United States Food and Drug Administration Investigational Device Exemption study began, with cases followed for 28-46 months (average, 32). Ninety-six percent of the investigational Device Exemption study cases had severe, disabling back pain; in addition, 74% had major annular degeneration; 57% had herniations; 21% had osteophytes; and 43% had disc height reduced by greater than 10%. Forty-five percent of cases had previous spinal surgeries, and none were posterior lumbar interbody fusions. Titanium fusion cage pairs were screwed into bored and threaded, parallel intradiscal holes, and 3-8 ml autologous cancellous bone was packed inside each. Fusion success was judged by absence of motion on flexion-extension radiographs, absence of bone halo around the implants, and maintenance of visible bone inside the cages on Ferguson view radiographs. RESULTS: Segments fused rapidly; the pilot study cases fused at 10 (91%) of 11 levels, with a reported 80% average clinical improvement. Ninety-six percent of the 208 2-year follow-up Investigational Device Exemption cases had fusion, and the Prolo socioeconomic/ functional improvement scale showed: 40% excellent, 25% good, 21% fair, and 14% poor results. Less than 1% of Investigational Device Exemption cases had complications that persisted beyond the average 5 days of hospitalization, and none were serious. CONCLUSIONS: The Ray titanium fusion cage (Surgical Dynamics, Norwalk, CT) implant method has been found to be an effective, rapid, safe procedure for lumbar spine fusions, demonstrating a high fusion rate and clinical success with rare, serious, or permanent complications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Boden, S. D., Zdeblick, T. A., Sandhu, H. S., & Heim, S. E. (2000) · Spine · doi:10.1097/00007632-200002010-00020 · Cited by 667
Schwender, J. D., Holly, L. T., Rouben, D. P., & Foley, K. T. (2005) · Journal of Spinal Disorders & Techniques · doi:10.1097/01.bsd.0000132291.50455.d0 · Cited by 561
In vitro and in vivo degradation of bioabsorbable PLLA spinal fusion cages
van Dijk, M., Tunc, D. C., Smit, T. H., Higham, P., Burger, E. H., & Wuisman, P. I. J. M. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10466 · Cited by 78
Metadata
- Authors
- Ray, C. D.
- Venue
- Spine
- Published
- 1997-03
- Volume
- 22
- Issue
- 6
- Pages
- 667-679
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2316505255
- Cited by
- 452
- References
- 0
- FWCI
- 15.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Threaded Titanium Cages for Lumbar Interbody Fusions. https://app.cochat.ai/papers/10.1097/00007632-199703150-00019
- The paper
- Ray, C. D. (1997). Threaded Titanium Cages for Lumbar Interbody Fusions. Spine. https://doi.org/10.1097/00007632-199703150-00019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.