Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 204

The DOI matches its Crossref record.

A Comparison of Manual Versus Computer-Assisted Radiographic Measurement: Intraobserver Measurement Variability for Cobb Angles

Shea, Kevin G., Stevens, Peter M., Nelson, Mark, Smith, John T., Masters, Kevin S., Yandow, Suzanne · 1998 · Spine

Abstract

STUDY DESIGN: A comparison between computer-assisted measurement using digitized radiographs, which has the potential to reduce error, and manual measurement using standard radiographs. OBJECTIVE: To assess measurement variability for the Cobb method on digital radiographs and compare it with that of manual measurements on standard radiographs. BACKGROUND DATA: Studies of the Cobb method have demonstrated multiple sources of error leading to significant intraobserver measurement variability. Estimates for the 95% confidence interval for intraobserver variability range from 2.8 degrees to 10 degrees. METHODS: Twenty-four scoliosis radiographs were measured by six examiners. Two measurement sets were done manually ("manual set"), and two measurement sets were done on digitized images using a computer mouse ("computer set"). RESULTS: For the manual set, the 95% confidence interval for intraobserver variability was 3.3 degrees (range, 2.5-4.5 degrees). For the computer set, the value was 2.6 degrees (range, 2.3-3.3 degrees). This difference in 95% confidence intervals between the manual and computer sets was statistically significant (P < 0.001). CONCLUSIONS: The results of this study demonstrate that intraobserver variability for manual and computer Cobb angle measurements yield a 95% confidence interval of approximately 3 degrees, with the computer having a slightly lower variability. The computer technique removes sources of intrinsic error, e.g., the variability introduced by using different manual protractors, the inaccuracy of standard protractors, and the use of wide-diameter radiographic markers. Identical digital images can be shared electronically between centers, without having to duplicate and mail films. Multicenter studies in which different examiners will be measuring Cobb angles may consider using the computer as a measuring device to reduce intrinsic measurement errors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00007632-199803010-00007

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 204

Metadata

Authors
Shea, K. G., Stevens, P. M., Nelson, M., Smith, J. T., Masters, K. S., & Yandow, S.
Venue
Spine
Published
1998-03
Volume
23
Issue
5
Pages
551-555
ISSN
0362-2436 (ISSN-L)
OpenAlex
W2328221614
Cited by
204
References
0
FWCI
4.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Comparison of Manual Versus Computer-Assisted Radiographic Measurement: Intraobserver Measurement Variability for Cobb Angles. https://app.cochat.ai/papers/10.1097/00007632-199803010-00007
The paper
Shea, K. G., Stevens, P. M., Nelson, M., Smith, J. T., Masters, K. S., & Yandow, S. (1998). A Comparison of Manual Versus Computer-Assisted Radiographic Measurement: Intraobserver Measurement Variability for Cobb Angles. Spine. https://doi.org/10.1097/00007632-199803010-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.