The DOI matches its Crossref record.
A Comparison of Manual Versus Computer-Assisted Radiographic Measurement: Intraobserver Measurement Variability for Cobb Angles
Abstract
STUDY DESIGN: A comparison between computer-assisted measurement using digitized radiographs, which has the potential to reduce error, and manual measurement using standard radiographs. OBJECTIVE: To assess measurement variability for the Cobb method on digital radiographs and compare it with that of manual measurements on standard radiographs. BACKGROUND DATA: Studies of the Cobb method have demonstrated multiple sources of error leading to significant intraobserver measurement variability. Estimates for the 95% confidence interval for intraobserver variability range from 2.8 degrees to 10 degrees. METHODS: Twenty-four scoliosis radiographs were measured by six examiners. Two measurement sets were done manually ("manual set"), and two measurement sets were done on digitized images using a computer mouse ("computer set"). RESULTS: For the manual set, the 95% confidence interval for intraobserver variability was 3.3 degrees (range, 2.5-4.5 degrees). For the computer set, the value was 2.6 degrees (range, 2.3-3.3 degrees). This difference in 95% confidence intervals between the manual and computer sets was statistically significant (P < 0.001). CONCLUSIONS: The results of this study demonstrate that intraobserver variability for manual and computer Cobb angle measurements yield a 95% confidence interval of approximately 3 degrees, with the computer having a slightly lower variability. The computer technique removes sources of intrinsic error, e.g., the variability introduced by using different manual protractors, the inaccuracy of standard protractors, and the use of wide-diameter radiographic markers. Identical digital images can be shared electronically between centers, without having to duplicate and mail films. Multicenter studies in which different examiners will be measuring Cobb angles may consider using the computer as a measuring device to reduce intrinsic measurement errors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Vertebroplasty and Kyphoplasty: A Systematic Review of 69 Clinical Studies
Hulme, P. A., Krebs, J., Ferguson, S. J., & Berlemann, U. (2006) · Spine · doi:10.1097/01.brs.0000229254.89952.6b · Cited by 754
Validation of new clinical quantitative analysis software applicable in spine orthopaedic studies
Champain, S., Benchikh, K., Nogier, A., Mazel, C., Guise, J. D., & Skalli, W. (2006) · European Spine Journal · doi:10.1007/s00586-005-0927-1 · Cited by 297
Monticone, M., Ambrosini, E., Cazzaniga, D., Rocca, B., & Ferrante, S. (2014) · European Spine Journal · doi:10.1007/s00586-014-3241-y · Cited by 277
A review of methods for quantitative evaluation of spinal curvature
Vrtovec, T., Pernuš, F., & Likar, B. (2009) · European Spine Journal · doi:10.1007/s00586-009-0913-0 · Cited by 263
The Relationship between Posterior Tibial Slope and Anterior Cruciate Ligament Injuries
Todd, M. S., Lalliss, S., Garcia, E., DeBerardino, T. M., & Cameron, K. L. (2010) · The American Journal of Sports Medicine · doi:10.1177/0363546509343198 · Cited by 256
Metadata
- Authors
- Shea, K. G., Stevens, P. M., Nelson, M., Smith, J. T., Masters, K. S., & Yandow, S.
- Venue
- Spine
- Published
- 1998-03
- Volume
- 23
- Issue
- 5
- Pages
- 551-555
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2328221614
- Cited by
- 204
- References
- 0
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Comparison of Manual Versus Computer-Assisted Radiographic Measurement: Intraobserver Measurement Variability for Cobb Angles. https://app.cochat.ai/papers/10.1097/00007632-199803010-00007
- The paper
- Shea, K. G., Stevens, P. M., Nelson, M., Smith, J. T., Masters, K. S., & Yandow, S. (1998). A Comparison of Manual Versus Computer-Assisted Radiographic Measurement: Intraobserver Measurement Variability for Cobb Angles. Spine. https://doi.org/10.1097/00007632-199803010-00007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.