The DOI matches its Crossref record.
Accuracy of Blind Versus Fluoroscopically Guided Caudal Epidural Injection
Abstract
STUDY DESIGN: A prospective observational study of a case series of patients with low back pain referred for epidural injection of corticosteroid. OBJECTIVES: To evaluate the accuracy of caudal epidural injections performed without the use of fluoroscopic guidance and to determine the value of specific clinical tests performed during the procedure in predicting successful epidural needle placement. SUMMARY OF BACKGROUND DATA: Epidural injection of corticosteroid is one of many treatments currently used in the nonsurgical management of low back pain. The face validity of many studies evaluating the efficacy of epidural corticosteroid injections has been criticized for use of a blind technique. Although there currently is no consensus in the spine literature as to whether epidural injection of corticosteroid (by any technique) is effective, it is imperative first to establish the accuracy of the technique being used. METHODS: A total of 54 consecutive patients underwent fluoroscopically guided caudal epidural injections. Needle insertion was performed blindly (without the use of fluoroscopic guidance), and the success of needle placement was predicted according to the presence of palpable landmarks, palpation of subcutaneous airflow, and the subjective impression that the needle was in a satisfactory position. These clinical criteria then were compared with the position of the needle as seen under fluoroscopy and the spread of radio-opaque contrast in the epidural space after the procedure. RESULTS: Successful injection placement on the first attempt occurred in 74.1% of the patients. Results were improved when anatomic landmarks were identified easily (87.5%) and no air was palpable subcutaneously over the sacrum when injected through the needle (82.9%). The combination of these two signs predicted a successful injection in 91.3% of attempts. CONCLUSIONS: Caudal epidural injection is performed ideally with fluoroscopic guidance as the gold standard for accurate drug placement. If fluoroscopic guidance is unavailable, impractical, or contraindicated, the presence of readily palpable anatomic landmarks at the sacral hiatus and the absence of palpable subcutaneous airflow over the sacrum significantly increase the operator's confidence in the likelihood of an accurate injection even before any products are administered into the epidural space.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kreiner, D. S., Hwang, S. W., Easa, J. E., Resnick, D. K., Baisden, J. L., Bess, S., Cho, C. H., DePalma, M. J., Dougherty, P., Fernand, R., et al. (2014) · The Spine Journal · doi:10.1016/j.spinee.2013.08.003 · Cited by 724
ASIPP, A. (2007) · Pain Physician · doi:10.36076/ppj.2007/10/7 · Cited by 519
Kreiner, D. S., Shaffer, W. O., Baisden, J. L., Gilbert, T. J., Summers, J. T., Toton, J. F., Hwang, S. W., Mendel, R. C., & Reitman, C. A. (2013) · The Spine Journal · doi:10.1016/j.spinee.2012.11.059 · Cited by 517
Chan, C.-W., & Peng, P. (2011) · Pain Medicine · doi:10.1111/j.1526-4637.2011.01089.x · Cited by 452
Manchikanti, L. (2009) · Pain Physician · doi:10.36076/ppj.2009/12/699 · Cited by 425
Metadata
- Authors
- Stitz, M. Y., & Sommer, H. M.
- Venue
- Spine
- Published
- 1999-07
- Volume
- 24
- Issue
- 13
- Pages
- 1371
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2022740492
- Cited by
- 201
- References
- 0
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of Blind Versus Fluoroscopically Guided Caudal Epidural Injection. https://app.cochat.ai/papers/10.1097/00007632-199907010-00016
- The paper
- Stitz, M. Y., & Sommer, H. M. (1999). Accuracy of Blind Versus Fluoroscopically Guided Caudal Epidural Injection. Spine. https://doi.org/10.1097/00007632-199907010-00016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.