The DOI matches its Crossref record.
Comparative Results Between Conventional and Computer-Assisted Pedicle Screw Installation in the Thoracic, Lumbar, and Sacral Spine
Abstract
STUDY DESIGN: A comparative study on the position of pedicle screws in patients treated surgically with and without computer assistance. OBJECTIVES: To evaluate the accuracy of computer-assisted pedicle screw installation, and to evaluate its clinical benefit as compared with conventional pedicle screw installation techniques. SUMMARY OF BACKGROUND DATA: In vitro and clinical studies have documented a significant rate of misplaced screws in the thoracolumbar area. Neurologic complications are recognized problems caused by screw misplacement. METHODS: Patients treated surgically with computer assistance were compared with a historical control group of patients treated surgically with conventional techniques in the same hospital and by the same surgical team. All screw positions were measured with a postoperative magnetic resonance tomography, and cortical effractions were categorized in 2-mm increments. Patients' charts also were reviewed to assess individual neurologic outcomes. RESULTS: The control cohort was composed of 100 patients, with 544 screws from T5 to S1. The computer-assisted cohort was composed of 50 patients, with 294 screws from T2 to S1. In the control cohort, 461 of 544 screws (85%) were found completely within their pedicles as compared with 278 of 294 screws (95%) correctly placed in the computer-assisted group (P < 0.0001). All 16 screws incorrectly placed with computer assistance were found 0.1 mm to 2 mm from the pedicle cortex. In the control cohort, 68 screws were found 0.1 mm to 2 mm, 10 screws 2.1 mm to 4 mm, and 5 screws more than 4 mm from the pedicle cortex. Seven patients in the control cohort were surgically retreated because of postoperative neurologic deficits, whereas no patients in the computer-assisted group were surgically retreated. CONCLUSIONS: Computer assistance can decrease the incidence of incorrectly positioned pedicle screws.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Accuracy of augmented reality-assisted pedicle screw placement: A systematic review
Youssef, S., McDonnell, J. M., Wilson, K. V., Turley, L., Cunniffe, G., Morris, S., Darwish, S., & Butler, J. S. (2024) · European Spine Journal · doi:10.1007/s00586-023-08094-5 · Cited by 36
“…accuracy between freehand and computer-aided placement using augmented reality, Amiot et al. found that in screws placed between T5 and S1, freehand placement had an error rate of 15.3% from 544 cases, whereas there was a 5.4% error rate from 294 cases when computer-assistance was used [42].”
Influential
Metadata
- Authors
- Amiot, L.-P., Lang, K., Putzier, M., Zippel, H., & Labelle, H.
- Venue
- Spine
- Published
- 2000-03
- Volume
- 25
- Issue
- 5
- Pages
- 606-614
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2063177025
- Cited by
- 450
- References
- 0
- FWCI
- 18.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.