The DOI matches its Crossref record.
Evaluation of OP-1 as a Graft Substitute for Intertransverse Process Lumbar Fusion
Abstract
STUDY DESIGN: An established rabbit intertransverse process lumbar fusion model was used to evaluate osteogenic protein (OP)-1 as a potential graft substitute. OBJECTIVES: To determine whether OP-1 is effective in producing intertransverse process lumbar fusion in a rabbit model. SUMMARY OF BACKGROUND DATA: Autogenous iliac crest bone is the gold standard in grafting material for inducing intertransverse process fusion. However, bone graft substitutes are being considered as supplementary or alternative means to achieve such fusion with less morbidity. Relatively little research has been undertaken to investigate the efficacy of OP-1 in this role. METHODS: Single-level intertransverse process lumbar fusions were performed at L5-L6 of 31 New Zealand White rabbits. These were divided into three study groups: autograft, carrier alone, and carrier with OP-1. The animals were killed 5 weeks after surgery. Resultant fusion masses were evaluated by manual palpation, radiography, biomechanical multidirectional flexibility testing, and histology. RESULTS: Seven rabbits (23%) were excluded because of complications. Of the remaining 24 rabbits, 5 (63%) of the 8 in the autograft group had fusion detected by manual palpation, none (0%) of the 8 in the carrier-alone group had fusion, and all 8 (100%) in the OP-1 group had fusion. Radiographs were 55% sensitive and 92% specific for determining fusion. Biomechanical testing results correlated well with those of manual palpation. Histologically, autograft specimens were predominantly fibrocartilage, OP-1 specimens were predominantly maturing bone, and carrier-alone specimens did not show significant bone formation. CONCLUSIONS: OP-1 was found to reliably induce solid intertransverse process fusion in a rabbit model at 5 weeks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Friedlaender, G. E., Perry, C. R., Cole, J. D., Cook, S. D., Cierny, G., Muschler, G. F., Zych, G. A., Calhoun, J. H., LaForte, A. J., & Yin, S. (2001) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200100002-00010 · Cited by 957
Self-citationBoden, S. D., Kang, J., Sandhu, H., & Heller, J. G. (2002) · Spine · doi:10.1097/00007632-200212010-00005 · Cited by 693
Polymeric Growth Factor Delivery Strategies for Tissue Engineering
Chen, R. R., & Mooney, D. J. (2003) · Pharmaceutical Research · doi:10.1023/a:1025034925152 · Cited by 435
Safety Profile for the Clinical Use of Bone Morphogenetic Proteins in the Spine
Poynton, A. R., & Lane, J. M. (2002) · Spine · doi:10.1097/00007632-200208151-00010 · Cited by 403
Metadata
- Authors
- Grauer, J. N., Patel, T. C., Erulkar, J. S., Troiano, N. W., Panjabi, M. M., & Friedlaender, G. E.
- Venue
- Spine
- Published
- 2001-01
- Volume
- 26
- Issue
- 2
- Pages
- 127-133
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2396612042
- Cited by
- 176
- References
- 0
- FWCI
- 11.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of OP-1 as a Graft Substitute for Intertransverse Process Lumbar Fusion. https://app.cochat.ai/papers/10.1097/00007632-200101150-00004
- The paper
- Grauer, J. N., Patel, T. C., Erulkar, J. S., Troiano, N. W., Panjabi, M. M., & Friedlaender, G. E. (2001). Evaluation of OP-1 as a Graft Substitute for Intertransverse Process Lumbar Fusion. Spine. https://doi.org/10.1097/00007632-200101150-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.