The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Radiographic Analysis of Lumbar Lordosis: Centroid, Cobb, TRALL, and Harrison Posterior Tangent Methods
Abstract
STUDY DESIGN: Delayed, repeated measures, with three examiners each twice digitizing thirty lateral lumbar radiographs. OBJECTIVES: To determine the reliability and clinical utility of the centroid, Cobb, tangential radiologic assessment of lumbar lordosis (TRALL), and Harrison posterior tangent line-drawing methods for analysis of lumbar lordosis. BACKGROUND DATA: Cobb's method is commonly used for curvature analysis on lateral lumbar radiographs, whereas the centroid, TRALL, and Harrison posterior tangent methods are not widely used. METHODS: Thirty lateral lumbar radiographs were digitized twice by each of three examiners. To evaluate reliability of determining global and segmental alignment, all four vertebral body corners of T12-S1 and the superior margin of the femur head were digitized. Angles created were segmental and global centroid, (two-line) Cobb angles, and intersections of posterior tangents. A global TRALL angle was determined. Means, standard deviations, mean absolute differences, interclass and intraclass correlation coefficients (ICC), and confidence intervals were calculated. RESULTS: The interobserver and intraobserver reliabilities of measuring all segmental and global angles were in the high range (ICCs > 0.83). The mean absolute differences of observers' measurements were small (0.6 degrees -2.0 degrees ). Distal segmental (L4-S1) and global angles of lumbar curvature were dependent on the method of measurement. CONCLUSIONS: All four radiographic methods had high reliability and low mean absolute differences of observers' measurements. Because it lacks a segmental analysis, the TRALL method is not recommended. The centroid, Cobb, and Harrison posterior tangent methods provide global and segmental angles. However, the centroid segmental method requires three segments and is less useful for a stability analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Cited by
Mannion, A. F., Knecht, K., Balaban, G., Dvorak, J., & Grob, D. (2004) · European Spine Journal · doi:10.1007/s00586-003-0618-8 · Cited by 396
A review of methods for quantitative evaluation of spinal curvature
Vrtovec, T., Pernuš, F., & Likar, B. (2009) · European Spine Journal · doi:10.1007/s00586-009-0913-0 · Cited by 263
Lang-Tapia, M., España-Romero, V., Anelo, J., & Castillo, M. J. (2011) · Journal of Applied Biomechanics · doi:10.1123/jab.27.2.143 · Cited by 54
Metadata
- Authors
- Harrison, D. E., Harrison, D. D., Cailliet, R., Janik, T. J., & Holland, B.
- Venue
- Spine
- Published
- 2001-06
- Volume
- 26
- Issue
- 11
- Pages
- e235-e242
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2050128306
- Cited by
- 238
- References
- 1
- FWCI
- 4.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radiographic Analysis of Lumbar Lordosis: Centroid, Cobb, TRALL, and Harrison Posterior Tangent Methods. https://app.cochat.ai/papers/10.1097/00007632-200106010-00003
- The paper
- Harrison, D. E., Harrison, D. D., Cailliet, R., Janik, T. J., & Holland, B. (2001). Radiographic Analysis of Lumbar Lordosis: Centroid, Cobb, TRALL, and Harrison Posterior Tangent Methods. Spine. https://doi.org/10.1097/00007632-200106010-00003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.