CoChat

Evaluation of Caffeine as an In Vivo Probe for CYP1A2 Using Measurements in Plasma, Saliva, and Urine

Carrillo, Juan A., Christensen, Magnus, Ramos, Sara I., Alm, Christina, Dahl, Marja-Liisa, Benítez, Julio, Bertilsson, Leif · 2000 · Therapeutic Drug Monitoring
Cited by 136

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Twenty-five healthy volunteers were given 100 mg caffeine orally and several estimates of cytochrome P450 1A2 (CYP1A2) activity were evaluated. The validation was performed by correlation of different parameters in plasma, saliva, and urine to two measures of caffeine clearance, CL(oral) and CL(137X-->17X) that served as standards of reference. Two subjects were excluded because of noncompliance with a caffeine-free diet. In the remaining 23 subjects, both plasma and saliva total clearances of caffeine were highly correlated with each other (r(s) = 0.97, p < 0.0001). The ratio 17X/137X restricted to one sampling point taken 4 hours after dose, showed a high correlation (r(s)) with CL(oral) and CL(137X-->17X) in plasma (0.84/0.83) and saliva (0.82/0.77) (p < 0.0001 for all the correlation values) where 17X is 1,7-dimethylxanthine (paraxanthine) and 137X is 1,3,7-trimethylxanthine (caffeine). Additionally, the ratio (AFMU + 1U + 1X + 17U + 17X)/137X in a 0-24 hours urine sampling showed the highest correlation with CL(137X-->17X) (r(s) = 0.85, p < 0.001) where AFMU is 5-acetylamino-6-formylamino-3-methyluracil, 1U is 1-methyluracil, 1X is 1-methylxanthine, and 17U is 1,7-dimethyluric acid. The major estimates of CYP1A2 activity were significantly less in nonsmoking females, and this probably was related to the use of oral contraceptives in this subpopulation. In summary, among caffeine-based approaches for CYP1A2, the authors recommend either plasma or saliva 17X/137X ratio and the urinary (AFMU + 1U + 1X + 17U + 17X)/137X ratio during a sampling interval of at least 8 hours, starting at time zero since caffeine intake. These indices are simple, reliable, and relatively inexpensive estimates of CYP1A2 activity to be used in the study of human populations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00007691-200008000-00008

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 136

Metadata

Authors
Carrillo, J. A., Christensen, M., Ramos, S. I., Alm, C., Dahl, M.-L., Benítez, J., & Bertilsson, L.
Venue
Therapeutic Drug Monitoring
Published
2000-08
Volume
22
Issue
4
Pages
409-417
ISSN
0163-4356 (ISSN-L)
OpenAlex
W2021097015
Cited by
136
References
2
FWCI
4.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of Caffeine as an In Vivo Probe for CYP1A2 Using Measurements in Plasma, Saliva, and Urine. https://app.cochat.ai/papers/10.1097/00007691-200008000-00008
The paper
Carrillo, J. A., Christensen, M., Ramos, S. I., Alm, C., Dahl, M.-L., Benítez, J., & Bertilsson, L. (2000). Evaluation of Caffeine as an In Vivo Probe for CYP1A2 Using Measurements in Plasma, Saliva, and Urine. Therapeutic Drug Monitoring. https://doi.org/10.1097/00007691-200008000-00008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.