The DOI matches its Crossref record.
INEFFECTIVENESS OF DIPYRIDAMOLE SPECT THALLIUM IMAGING AS A SCREENING TECHNIQUE FOR CORONARY ARTERY DISEASE IN PATIENTS WITH END-STAGE RENAL FAILURE
Abstract
The efficacy of dipyridamole single photon emission computed tomography (SPECT) thallium as a screening test for coronary artery disease (CAD), was studied in 45 patients with end-stage renal failure undergoing evaluation for renal transplantation. Coronary arteriography, dipyridamole SPECT thallium imaging and clinical follow-up were performed in all patients. Nineteen patients (42%) had an obstruction of 50% or more in at least one coronary artery. Fourteen patients had a positive thallium scan, but 7 of these were false-positives (sensitivity 37%, specificity 73%). The sensitivity was considerably lower than that quoted for non-ESRF patients in the literature, and significantly lower than a control group of 19 patients without ESRF having comparable severity and distribution of CAD. Five of the 6 patients who died of cardiac causes over a mean follow-up period of 25 months had normal thallium imaging, but all had significant coronary artery disease at cardiac catheterization. Dipyridamole SPECT thallium imaging has not proved a useful screening test for angiographically significant CAD, and does not predict cardiac prognosis in this population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Herzog, C. A., Asinger, R. W., Berger, A. K., Charytan, D. M., Díez, J., Hart, R. G., Eckardt, K.-U., Kasiske, B. L., McCullough, P. A., Passman, R. S., et al. (2011) · Kidney International · doi:10.1038/ki.2011.223 · Cited by 922
Cardiac Disease Evaluation and Management Among Kidney and Liver Transplantation Candidates
Lentine, K. L., Costa, S. P., Weir, M. R., Robb, J. F., Fleisher, L. A., Kasiske, B. L., Carithers, R. L., Ragosta, M., Bolton, K., Auerbach, A. D., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.05.008 · Cited by 399
Prognostic value of thallium-201 myocardial perfusion imaging. A diagnostic tool comes of age.
Brown, K. A. (1991) · Circulation · doi:10.1161/01.cir.83.2.363 · Cited by 390
Coronary revascularisation in insulin-dependent diabetic patients with chronic renal failure
Manske, C. L., Wang, Y., Rector, T., Wilson, R. F., & White, C. W. (1992) · The Lancet · doi:10.1016/0140-6736(92)93010-k · Cited by 359
Lentine, K. L., Costa, S. P., Weir, M. R., Robb, J. F., Fleisher, L. A., Kasiske, B. L., Carithers, R. L., Ragosta, M., Bolton, K., Auerbach, A. D., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31823eb07a · Cited by 314
Metadata
- Authors
- MARWICK, T. H., STEINMULLER, D. R., UNDERWOOD, D. A., HOBBS, R. E., GO, R. T., SWIFT, C., & BRAUN, W. E.
- Venue
- Transplantation
- Published
- 1990-01
- Volume
- 49
- Issue
- 1
- Pages
- 100-102
- ISSN
- 0041-1337 (ISSN-L)
- OpenAlex
- W2069641647
- Cited by
- 200
- References
- 0
- FWCI
- 3.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: INEFFECTIVENESS OF DIPYRIDAMOLE SPECT THALLIUM IMAGING AS A SCREENING TECHNIQUE FOR CORONARY ARTERY DISEASE IN PATIENTS WITH END-STAGE RENAL FAILURE. https://app.cochat.ai/papers/10.1097/00007890-199001000-00022
- The paper
- MARWICK, T. H., STEINMULLER, D. R., UNDERWOOD, D. A., HOBBS, R. E., GO, R. T., SWIFT, C., & BRAUN, W. E. (1990). INEFFECTIVENESS OF DIPYRIDAMOLE SPECT THALLIUM IMAGING AS A SCREENING TECHNIQUE FOR CORONARY ARTERY DISEASE IN PATIENTS WITH END-STAGE RENAL FAILURE. Transplantation. https://doi.org/10.1097/00007890-199001000-00022
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.