DELIVERY OF WHOLE LIVER-EQUIVALENT HEPATOCYTE MASS USING POLYMER DEVICES AND HEPATOTROPHIC STIMULATION
The DOI matches its Crossref record.
Abstract
Using hepatocytes injected into prevascularized polymer sponge devices, we studied hepatocyte survival and function after delivery of a whole liver-equivalent of cells into rats. LEW rats and enzyme-deficient Gunn rats served as recipients, respectively. Totally, 28.5 cm2 (0.5-cm thick) of polyvinyl alcohol sponges were implanted per animal. Hepatotrophic stimulation was induced by portacaval shunt and partial (70% or 30%) hepatectomy. Recipient rats received 5 x 10(8) hepatocytes (equivalent to whole rat liver) which were harvested from LEW and Wistar donors, respectively. After engraftment, histologic examination revealed hepatocyte remodeling in the device with capillaries lining plates of hepatocytes, and also tubular structures resembling early biliary radicles. BrdU staining revealed DNA synthesis in hepatocytes, providing evidence of regeneration within the grafts. Quantification of viable hepatocyte area at various time points was performed using computer-assisted morphometry. We then estimated a range of cell numbers from the quantitated cell area. The number of hepatocytes viable at day 7 was estimated at 27.5-46.0% and 6.6-11.0% in the mesentery and subcutaneous site, respectively. Thus the average number was estimated between 10.8% and 18.0% of initially injected hepatocytes. In the Gunn rat experiment, experimental rats that received normal Wistar hepatocytes showed a significantly greater decrease in total serum bilirubin compared with the concurrent control Gunn rats (P < 0.01). At week 1, serum bilirubin in experimental rats decreased to 74.7% (6.80 +/- 0.46 mg/dl) of pretransplantation level (9.10 +/- 0.47 mg/dl) and this was 71.4% of the control rats' bilirubin level (9.53 +/- 0.37 mg/dl). In conclusion, a hepatocyte mass equivalent to a whole rat liver can be delivered into prevascularized polymer sponge devices. At day 7 between 10.8% and 18.0% of these hepatocytes were estimated to be engrafted and functioning. Further optimization of this technique is necessary before clinical application is considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
Self-citationBiodegradable Polymer Scaffolds for Tissue Engineering
Freed, L. E., Vunjak-Novakovic, G., Biron, R. J., Eagles, D. B., Lesnoy, D. C., Barlow, S. K., & Langer, R. (1994) · Nature Biotechnology · doi:10.1038/nbt0794-689 · Cited by 1,235
Fabrication of biodegradable polymer scaffolds to engineer trabecular bone
Thomson, R. C., Yaszemski, M. J., Powers, J. M., & Mikos, A. G. (1996) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856295x00805 · Cited by 493
Biodegradable polymer scaffolds to regenerate organs
Thomson, R. C., Wake, M. C., Yaszemski, M. J., & Mikos, A. G. (1995) · Advances in Polymer Science · doi:10.1007/3540587888_18 · Cited by 383
Transplantation of cells in matrices for tissue regeneration
Marler, J. J., Upton, J., Langer, R., & Vacanti, J. P. (1998) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(98)00025-8 · Cited by 377
Self-citation
Metadata
- Authors
- UVAMA, S., KAUFMANN, P.-M., TAKEDA, T., & VACANTI, J. P.
- Venue
- Transplantation
- Published
- 1993-04
- Volume
- 55
- Issue
- 4
- Pages
- 932-935
- ISSN
- 0041-1337 (ISSN-L)
- OpenAlex
- W2088211007
- Cited by
- 115
- References
- 0
- FWCI
- 15.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: DELIVERY OF WHOLE LIVER-EQUIVALENT HEPATOCYTE MASS USING POLYMER DEVICES AND HEPATOTROPHIC STIMULATION. https://app.cochat.ai/papers/10.1097/00007890-199304000-00044
- The paper
- UVAMA, S., KAUFMANN, P.-M., TAKEDA, T., & VACANTI, J. P. (1993). DELIVERY OF WHOLE LIVER-EQUIVALENT HEPATOCYTE MASS USING POLYMER DEVICES AND HEPATOTROPHIC STIMULATION. Transplantation. https://doi.org/10.1097/00007890-199304000-00044
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.