Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 163

The DOI matches its Crossref record.

UTILITY OF TRANSVENOUS LIVER BIOPSIES AND WEDGED HEPATIC VENOUS PRESSURE MEASUREMENTS IN SIXTY MARROW TRANSPLANT RECIPIENTS

Shulman, Howard M., Gooley, Ted, Dudley, M Dick, Kofler, Thomas, Feldman, Robert, Dwyer, David, McDonald, George B.·1995·Transplantation

Abstract

Sixty marrow transplant recipients with liver dysfunction underwent transvenous liver biopsy and measurement of the hepatic venous pressure gradient. Biopsies were done on 29 patients using a Cook needle inserted through the jugular vein, on 30 patients through the femoral vein with a Mansfield biopsy forceps, and on 1 patient using both instruments. The average number of evaluable portal spaces was 4.0 for aggregated Cook needle specimens and 5.2 for Mansfield forceps specimens. The average number of central venules was 2.6 for Cook needle specimens and 3.5 for Mansfield specimens. Tissue obtained with the Mansfield forceps had crush artifact, especially along the edges, making assessment of bile ducts more difficult than in Cook needle specimens. Liver histology aided management in 53/60 patients by confirming the clinical diagnosis in 24 (40%) and by providing additional diagnoses in 29 (48%). Hepatic venous pressure gradient > 10 mmHg correlated with a histologic diagnosis of veno-occlusive disease (P = 0.001); this gradient value provided 91% specificity and 86% positive predictive value. Eleven patients had bleeding complications, 9 after Cook needle biopsy and 2 after Mansfield forceps biopsy. There were 3 procedure-related deaths, 2 from intraperitoneal bleeding after Cook needle biopsy and 1 from femoral vein bleeding after Mansfield biopsy. We conclude that transvenous liver biopsy and pressure measurements provide useful diagnostic information in marrow transplant patients with liver disease. In our hands, the Mansfield forceps was associated with a lower risk of intra-abdominal bleeding and capsular perforation of the liver while providing adequate histology for diagnosis. Hepatic venous pressure gradients > 10 mmHg were highly specific for a diagnosis of veno-occlusive disease in this patient population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00007890-199504150-00017

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 163

Metadata

Authors
Shulman, H. M., Gooley, T., Dudley, M. D., Kofler, T., Feldman, R., Dwyer, D., & McDonald, G. B.
Venue
Transplantation
Published
1995-04
Volume
59
Issue
7
Pages
1015-1022
ISSN
0041-1337 (ISSN-L)
OpenAlex
W1987935161
Cited by
163
References
0
FWCI
1.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: UTILITY OF TRANSVENOUS LIVER BIOPSIES AND WEDGED HEPATIC VENOUS PRESSURE MEASUREMENTS IN SIXTY MARROW TRANSPLANT RECIPIENTS. https://app.cochat.ai/papers/10.1097/00007890-199504150-00017
The paper
Shulman, H. M., Gooley, T., Dudley, M. D., Kofler, T., Feldman, R., Dwyer, D., & McDonald, G. B. (1995). UTILITY OF TRANSVENOUS LIVER BIOPSIES AND WEDGED HEPATIC VENOUS PRESSURE MEASUREMENTS IN SIXTY MARROW TRANSPLANT RECIPIENTS. Transplantation. https://doi.org/10.1097/00007890-199504150-00017

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.