The DOI matches its Crossref record.
OUTCOME OF SUBCUTANEOUS ISLET TRANSPLANTATION IMPROVED BY POLYMER DEVICE1
Abstract
Syngeneic transplantation of rat islets into subcutaneous tissue failed to cure streptozocin diabetes. The reason is unknown, but poor vascularization may play a role. We hypothesize that if a well-vascularized subcutaneous site could be created, islet grafts would do well. Four hundred freshly isolated mouse islets were transplanted syngeneically under the renal capsule or into the intraperitoneal cavity and compared with 800 islets in subcutaneous tissue of streptozocin-diabetic mice. Four weeks after transplantation, 14 of 14 under the renal capsule, 4 of 8 in the intraperitoneal site, and 0 of 7 in the subcutaneous tissue site achieved normoglycemia. To create vascularized organoids, we transplanted 800 mouse islets into polyvinyl alcohol (PVA) or polyglycolic acid (PGA) polymers in subcutaneous tissue of streptozocin-diabetic mice either immediately (four in PVA and six in PGA) or 7 days (four in PVA and four in PGA) after implantation. Four weeks after transplantation, the mean blood glucose level and body weight had no change with PVA. However, the mean body weight increased significantly with PGA and 3/10 became normoglycemic. When transplanting 400 islets with PGA polymers intraperitoneally, all animals (n=5) remained hyperglycemic 3 months later. In contrast, four of five recipients transplanted with 800 islets with PGA polymers subcutaneously became normoglycemic. The grafts from successful animals contained numerous revascularized islets containing a substantial amount of insulin. These preliminary results indicate that subcutaneous islet transplantation using PGA polymers can improve the metabolic status and, in some cases, even cure diabetes in streptozocin-diabetic mice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
PVA–clay nanocomposite hydrogels for wound dressing
Kokabi, M., Sirousazar, M., & Hassan, Z. M. (2007) · European Polymer Journal · doi:10.1016/j.eurpolymj.2006.11.030 · Cited by 662
Host response to tissue engineered devices
Babensee, J. E., Anderson, J. M., McIntire, L. V., & Mikos, A. G. (1998) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(98)00023-4 · Cited by 585
Differentiation of Human Embryonic Stem Cells into Insulin‐Producing Clusters
Segev, H., Fishman, B., Ziskind, A., Shulman, M., & Itskovitz‐Eldor, J. (2004) · STEM CELLS · doi:10.1634/stemcells.22-3-265 · Cited by 346
Extracellular Matrix in Pancreatic Islets: Relevance to Scaffold Design and Transplantation
Stendahl, J. C., Kaufman, D. B., & Stupp, S. I. (2009) · Cell Transplantation · doi:10.3727/096368909788237195 · Cited by 333
Asran, A. S., Henning, S., & Michler, G. H. (2010) · Polymer · doi:10.1016/j.polymer.2009.12.046 · Cited by 279
Metadata
- Authors
- Juang, J.-H., Bonner-Weir, S., Ogawa, Y., Vacanti, J. P., & Weir, G. C.
- Venue
- Transplantation
- Published
- 1996-06
- Volume
- 61
- Issue
- 11
- Pages
- 1557-1561
- ISSN
- 0041-1337 (ISSN-L)
- OpenAlex
- W2023078563
- Cited by
- 163
- References
- 0
- FWCI
- 2.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: OUTCOME OF SUBCUTANEOUS ISLET TRANSPLANTATION IMPROVED BY POLYMER DEVICE1. https://app.cochat.ai/papers/10.1097/00007890-199606150-00001
- The paper
- Juang, J.-H., Bonner-Weir, S., Ogawa, Y., Vacanti, J. P., & Weir, G. C. (1996). OUTCOME OF SUBCUTANEOUS ISLET TRANSPLANTATION IMPROVED BY POLYMER DEVICE1. Transplantation. https://doi.org/10.1097/00007890-199606150-00001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.