Sensitivity in the clinical diagnosis of malignant melanoma
The DOI matches its Crossref record.
Abstract
Accurate clinical diagnosis of malignant melanoma is of great importance for early detection and further treatment. The purpose of this retrospective study was to evaluate the accuracy of clinical diagnosis by using different clinical and histopathological parameters. Calculations are based on a total of 44,258 histopathologically examined skin neoplasms, including 529 melanomas, which were recorded in the histological database of the Department of Dermatology, University of Graz during a 2 year period. The clinical diagnosis of the referring physicians was compared statistically with the final histopathological interpretation. Clinical diagnosis of melanoma showed a sensitivity of 70.1%, a specificity of 99.4%, and a positive predictive value of 60.7%. One hundred and fifty eight melanomas (29.9%) could not be diagnosed clinically. The age-dependent sensitivity was 47.6% in patients <40 years, whereas for patients >80 years the value was 90.2%. Remarkably, the sensitivity in melanomas >4 mm thickness (64.8%) was lower than in 'melanoma in situ' (72.6%). Our findings underline the importance of further development of clinical examination techniques such as dermoscopy and digital epiluminescence microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Carli, P., De Giorgi, V., Crocetti, E., Mannone, F., Massi, D., Chiarugi, A., & Giannotti, B. (2004) · British Journal of Dermatology · doi:10.1111/j.0007-0963.2004.05860.x · Cited by 243
Three-Point Checklist of Dermoscopy
Soyer, H. P., Argenziano, G., Zalaudek, I., Corona, R., Sera, F., Talamini, R., Barbato, F., Baroni, A., Cicale, L., Di Stefani, A., et al. (2004) · Dermatology · doi:10.1159/000075042 · Cited by 243
Self-citationAmelanotic/hypomelanotic melanoma: clinical and dermoscopic features
Pizzichetta, M. A., Talamini, R., Stanganelli, I., Puddu, P., Bono, R., Argenziano, G., Veronesi, A., Trevisan, G., Rabinovitz, H., & Soyer, H. P. (2004) · British Journal of Dermatology · doi:10.1111/j.1365-2133.2004.05928.x · Cited by 236
Self-citationDiagnostic Applicability of In Vivo Confocal Laser Scanning Microscopy in Melanocytic Skin Tumors
Gerger, A., Koller, S., Kern, T., Massone, C., Steiger, K., Richtig, E., Kerl, H., & Smolle, J. (2005) · Journal of Investigative Dermatology · doi:10.1111/j.0022-202x.2004.23569.x · Cited by 231
Self-citationLimitations of Dermoscopy in the Recognition of Melanoma
Skvara, H., Teban, L., Fiebiger, M., Binder, M., & Kittler, H. (2005) · Archives of Dermatology · doi:10.1001/archderm.141.2.155 · Cited by 197
“E ARLY RECOGNITION OF cutaneous melanoma is an ongoing challenge in dermatology.(1-4) Dermoscopy (dermatoscopy and epiluminescencemicroscopy)hasevolvedover20years and is now widely used for the examination of pigmented skin lesions.”
BackgroundGambichler, T., Regeniter, P., Bechara, F. G., Orlikov, A., Vasa, R., Moussa, G., Stücker, M., Altmeyer, P., & Hoffmann, K. (2007) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2007.05.029 · Cited by 175
Instruments and new technologies for the in vivo diagnosis of melanoma
Marghoob, A. A., Swindle, L. D., Moricz, C. Z. M., Sanchez Negron, F. A., Slue, B., Halpern, A. C., & Kopf, A. W. (2003) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(03)02470-8 · Cited by 174
Melanoma Screening with Cellular Phones
Massone, C., Hofmann-Wellenhof, R., Ahlgrimm-Siess, V., Gabler, G., Ebner, C., & Peter Soyer, H. (2007) · PLoS ONE · doi:10.1371/journal.pone.0000483 · Cited by 136
“[12] Moreover, the naked-eye examination based on the ABCD system may fail to detect the so called small melanomas as well as melanoma regular in shape and/or colour.[13] Dermoscopy (in the past also called epiluminescence microscopy, dermatoscopy, surface microscopy), a recent, noninvasive, in vivo technique, has the…”
Distance to Diagnosing Provider as a Measure of Access for Patients With Melanoma
Stitzenberg, K. B., Thomas, N. E., Dalton, K., Brier, S. E., Ollila, D. W., Berwick, M., Mattingly, D., & Millikan, R. C. (2007) · Archives of Dermatology · doi:10.1001/archderm.143.8.991 · Cited by 119
Tan, E., Yung, A., Jameson, M., Oakley, A., & Rademaker, M. (2010) · British Journal of Dermatology · doi:10.1111/j.1365-2133.2010.09673.x · Cited by 116
Bono, A., Tolomio, E., Trincone, S., Bartoli, C., Tomatis, S., Carbone, A., & Santinami, M. (2006) · British Journal of Dermatology · doi:10.1111/j.1365-2133.2006.07396.x · Cited by 78
The epidemiology, prevention, and detection of melanoma.
(2010) · PubMed Central · Cited by 54
Metadata
- Authors
- Wolf, I. H., Smolle, J., Soyer, H. P., & Kerl, H.
- Venue
- Melanoma Research
- Published
- 1998-10
- Volume
- 8
- Issue
- 5
- Pages
- 425-429
- ISSN
- 0960-8931 (ISSN-L)
- OpenAlex
- W2078122940
- Cited by
- 101
- References
- 0
- FWCI
- 1.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.