The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Lower Limb Prosthetic Outcome Measures: A Review of the Literature 1995 to 2005
Abstract
A systematic review of outcome measures used in the field of lower limb prosthetics between 1995 and 2005 shows a multitude of measures currently in use in prosthetic rehabilitation; however, there is no agreement on a gold standard. The review was based on a search of the University of Strathclyde's RECAL database and Medline. The search strategies were liberal so as to pick up all potential studies and specific to each database. Abstracts returned by the searches were scanned for relevance by at least two of the three authors. The full text of potentially relevant studies was then obtained and considered for inclusion in the review, again by at least two authors. Any disagreement was resolved with the third author. A data extraction form covering the areas of general information, practicality, reliability, validity, scaling, and potential for bias was developed. The search identified 340 articles, of which 28 met all inclusion criteria and were included in the review. A total of 25 measures were used as primary outcome measures, with many more as comparators. Reliability, validity, and scaling data as reported in the included studies are presented. Some recurring methodological flaws were noted and include inconsistent use of numbers and percentages, insufficient information on patient populations, no analysis of difference between response and nonresponse groups, and conclusions that tend to overstate findings. No single measure emerges as being universally appropriate. There are many measures in use with little agreement regarding which to use and when. Some measures do have proven validity and reliability and are easy to use. Many of the published studies are complex and difficult to read, which may limit the transfer of research findings into clinical practice. Terminology can be inconsistent and confusing. For measuring mobility, a timed walking test that incorporates a sit-to-stand and a turn, such as the timed up and go test, is highly appropriate for amputees. Generic, nonamputee specific measures of function and quality of life are inappropriate for lower limb amputees.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluating patient-based outcome measures for use in clinical trials.
Fitzpatrick, Davey, Buxton, & Jones (1998) · Health Technology Assessment · doi:10.3310/hta2140 · Cited by 1,715
Cited by
Outcomes in lower limb amputation following trauma: A systematic review and meta-analysis
Penn-Barwell, J. G. (2011) · Injury · doi:10.1016/j.injury.2011.07.005 · Cited by 283
Predicting walking ability following lower limb amputation: A systematic review of the literature
Sansam, K., Neumann, V, O’Connor, R., & Bhakta, B. (2009) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0393 · Cited by 268
Bekrater-Bodmann, R. (2022) · Consciousness and Cognition · doi:10.1016/j.concog.2021.103268 · Cited by 9
Metadata
- Authors
- Condie, E., Scott, H., & Treweek, S.
- Venue
- JPO Journal of Prosthetics and Orthotics
- Published
- 2006-01
- Volume
- 18
- Issue
- Proceedings
- Pages
- P13-P45
- ISSN
- 1040-8800 (ISSN-L)
- OpenAlex
- W1977105995
- Cited by
- 184
- References
- 1
- FWCI
- 3.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lower Limb Prosthetic Outcome Measures: A Review of the Literature 1995 to 2005. https://app.cochat.ai/papers/10.1097/00008526-200601001-00004
- The paper
- Condie, E., Scott, H., & Treweek, S. (2006). Lower Limb Prosthetic Outcome Measures: A Review of the Literature 1995 to 2005. JPO Journal of Prosthetics and Orthotics. https://doi.org/10.1097/00008526-200601001-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.