The DOI matches its Crossref record.
Simple and reliable CYP1A2 phenotyping by the paraxanthine/caffeine ratio in plasma and in saliva
Abstract
Several procedures to monitor CYP1A2 activity in vivo by the use of caffeine as a probe have been proposed. They comprise caffeine clearance, based on both plasma and saliva concentrations, urinary metabolite ratios, the 13C-caffeine breath test, and the paraxanthine/caffeine ratio in plasma. The latter method is fast, simple, economical and restricted to one sampling point. In this study, we retrospectively analysed four clinical trials comprising 78 subjects to validate the use of the paraxanthine/caffeine ratios in plasma and saliva for CYP1A2 activity. The validation was done by correlation of these ratios to the systemic caffeine clearance as a reference method. Additionally, urinary metabolite ratios and the caffeine breath test were included in the analysis. The paraxanthine/caffeine ratios in plasma and saliva preferably 5-7 h after administration of caffeine most closely resembled systemic caffeine clearance with correlation coefficients typically higher than r = 0.85. An equation to estimate systemic caffeine clearance from the paraxanthine/caffeine ratios taken at any time within 3-7 h postdose was developed. Correlations of systemic clearance with urinary metabolite ratios and the caffeine breath test were less reliable both in this investigation and in the literature. In conclusion, the paraxanthine/caffeine ratios in plasma and saliva appear a valid and inexpensive method of assessing CYP1A2 activity in vivo. Apparent distribution of CYP1A2 activity for all healthy subjects appeared bimodal in nonsmokers (n = 29) and smokers (n = 17).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Clinical Significance of the Cytochrome P450 2C19 Genetic Polymorphism
Desta, Z., Zhao, X., Shin, J.-G., & Flockhart, D. A. (2002) · Clinical Pharmacokinetics · doi:10.2165/00003088-200241120-00002 · Cited by 942
Pharmacokinetic Interactions with Rifampicin: Clinical Relevance
Niemi, M., Backman, J. T., Fromm, M. F., Neuvonen, P. J., & Kivist??, K. T. (2003) · Clinical Pharmacokinetics · doi:10.2165/00003088-200342090-00003 · Cited by 764
Sachse, C., Brockmöller, J., Bauer, S., & Roots, I. (1999) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.1999.00898.x · Cited by 751
Drug Interactions with Tobacco Smoking: An Update
Zevin, S., & Benowitz, N. L. (1999) · Clinical Pharmacokinetics · doi:10.2165/00003088-199936060-00004 · Cited by 692
Streetman, D. S., Bertino, J. S., & Nafziger, A. N. (2000) · Pharmacogenetics · doi:10.1097/00008571-200004000-00001 · Cited by 425
Metadata
- Authors
- Fuhr, U., & Rost, K. L.
- Venue
- Pharmacogenetics
- Published
- 1994-06
- Volume
- 4
- Issue
- 3
- Pages
- 109-116
- ISSN
- 0960-314X (ISSN-L)
- OpenAlex
- W1997287652
- Cited by
- 181
- References
- 0
- FWCI
- 6.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simple and reliable CYP1A2 phenotyping by the paraxanthine/caffeine ratio in plasma and in saliva. https://app.cochat.ai/papers/10.1097/00008571-199406000-00001
- The paper
- Fuhr, U., & Rost, K. L. (1994). Simple and reliable CYP1A2 phenotyping by the paraxanthine/caffeine ratio in plasma and in saliva. Pharmacogenetics. https://doi.org/10.1097/00008571-199406000-00001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.