EXTRACTION PROCEDURE FOR VOLATILE SELENIUM FROM ACTIVATED CARBON
The DOI matches its Crossref record.
Abstract
Activated carbon can be used to trap volatile selenium (Se) in long-term field experiments. Volatile Se is principally in the form of dimethyl selenide (DMSe). An extraction method was developed to oxidize alkylated Se compounds to inorganic selenate form with alkaline H2O2 and wash out from the charcoal filters. Alkaline H2O2 and water were compared as extractants in shaker and drip methods. Water extracted only 14.9% and 48.8% in shaker and drip methods, respectively in three consecutive extractions from a known quantity of DMSe. Both peroxide only and peroxide/water treatments extracted an average of 90% DMSe in shaker and drip methods. Therefore, it is concluded that using the drip method with alkaline H2O2, at least for the first extraction, is superior to extracting with water alone. To expedite the extraction procedure, all filters from each chamber were extracted together and tested with two different flow rates. It was found that the slow flow rate of 2.2 ml min−1 for a syringe of capacity 60 ml with an area of cross section of 5.7 cm2 extracted nearly 96% of DMSe and was slightly better than the flow rate of 3.3 ml min−1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Selenium Removal by Constructed Wetlands: Role of Biological Volatilization
Hansen, D., Duda, P. J., Zayed, A., & Terry, N. (1998) · Environmental Science & Technology · doi:10.1021/es970502l · Cited by 253
Wu, L. (2004) · Ecotoxicology and Environmental Safety · doi:10.1016/s0147-6513(03)00064-2 · Cited by 179
Bañuelos, G. S., Lin, Z.-Q., Arroyo, I., & Terry, N. (2005) · Chemosphere · doi:10.1016/j.chemosphere.2005.02.033 · Cited by 61
Bañuelos, G. S., & Lin, Z.-Q. (2007) · Environmental Pollution · doi:10.1016/j.envpol.2007.02.009 · Cited by 42
“Earlier studies showed that biological volatilization of Se varies greatly because of fluctuations in different physical, chemical, and biological factors in the field (Lin and Terry, 2003; Zhang and Frankenberger, 1999; Hansen et al., 1998; Rael et al., 1996; Frankenberger and Karlson, 1989, 1994a,b; Jayaweera and Bi…”
BackgroundDetermination of gaseous and particulate selenium over a rural grassland in the U.K.
Haygarth, P. M., Fowler, D., Stürup, S., Davison, B. M., & Tones, K. C. (1994) · Atmospheric Environment · doi:10.1016/1352-2310(94)00196-r · Cited by 21
Metadata
- Authors
- JAYAWEERA, G. R., & BIGGAR, J. W.
- Venue
- Soil Science
- Published
- 1992-04
- Volume
- 153
- Issue
- 4
- Pages
- 288-292
- ISSN
- 0038-075X (ISSN-L)
- OpenAlex
- W2040512622
- Cited by
- 14
- References
- 0
- FWCI
- 0.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: EXTRACTION PROCEDURE FOR VOLATILE SELENIUM FROM ACTIVATED CARBON. https://app.cochat.ai/papers/10.1097/00010694-199204000-00004
- The paper
- JAYAWEERA, G. R., & BIGGAR, J. W. (1992). EXTRACTION PROCEDURE FOR VOLATILE SELENIUM FROM ACTIVATED CARBON. Soil Science. https://doi.org/10.1097/00010694-199204000-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.