Cerebral Vessel Stenosis in Sickle Cell Disease: Criteria for Detection by Transcranial Doppler
The DOI matches its Crossref record.
Abstract
Ischemic stroke is a common and disabling complication of sickle cell disease (Hb SS). Most infarctions occur in the presence of intracranial stenotic lesions of the large vessels of the circle of Willis. Transcranial Doppler (TCD), by measuring flow velocity in these arterial segments, can detect focal stenosis on the basis of elevated flow velocity. We report the preliminary results of a prospective study to develop criteria for detection of stenotic lesions based on TCD and identification of patients with Hb SS at risk for stroke. Comparing the TCD findings from six patients with lesions demonstrated by angiography to those from 115 Hb SS children without stroke, we conclude: (a) middle cerebral (MCA), anterior cerebral (ACA), or internal carotid (ICA) artery mean velocities greater than 190 cm/s strongly suggest focal stenosis; (b) MCA or ACA mean velocities of 150 to 190 cm/s suggest abnormality but at present cannot be considered diagnostic of stenosis; (c) mean velocities up to 150 cm/s are possibly due to the effects of low hematocrit and/or young age, and cannot as yet be distinguished from velocity elevations due to vessel stenosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Use of Transcranial Ultrasonography to Predict Stroke in Sickle Cell Disease
Adams, R., McKie, V., Nichols, F., Carl, E., Zhang, D.-L., McKie, K., Figueroa, R., Litaker, M., Thompson, W., & Hess, D. (1992) · New England Journal of Medicine · doi:10.1056/nejm199202273260905 · Cited by 658
Self-citationLatchaw, R. E., Alberts, M. J., Lev, M. H., Connors, J. J., Harbaugh, R. E., Higashida, R. T., Hobson, R., Kidwell, C. S., Koroshetz, W. J., Mathews, V., et al. (2009) · Stroke · doi:10.1161/strokeaha.108.192616 · Cited by 452
Miller, S. T., Macklin, E. A., Pegelow, C. H., Kinney, T. R., Sleeper, L. A., Bello, J. A., DeWitt, L. D., Gallagher, D. M., Guarini, L., Moser, F. G., et al. (2001) · The Journal of Pediatrics · doi:10.1067/mpd.2001.117580 · Cited by 287
Hydroxyurea therapy lowers transcranial Doppler flow velocities in children with sickle cell anemia
Zimmerman, S. A., Schultz, W. H., Burgett, S., Mortier, N. A., & Ware, R. E. (2007) · Blood · doi:10.1182/blood-2006-11-057893 · Cited by 217
“6 maximum velocity (TAMV) was used to determine the TCD value for the major intracranial arteries on each side, as previously described [5].”
BackgroundMethodInfluentialNeurocognitive Sequelae of Pediatric Sickle Cell Disease: A Review of the Literature
Berkelhammer, L. D., Williamson, A. L., Sanford, S. D., Dirksen, C. L., Sharp, W. G., Margulies, A. S., & Prengler, R. A. (2007) · Child Neuropsychology · doi:10.1080/09297040600800956 · Cited by 171
“and, values greater than 200 are abnormal (Adams et al., 1990).”
Background
Metadata
- Authors
- Adams, R. J., Nichols, F. T., Aaslid, R., MCKie, V. C., MCKie, K., Carl, E., Stephens, S., Thompson, W. O., Milner, P., & Figueroa, R.
- Venue
- Journal of Pediatric Hematology/Oncology
- Published
- 1990
- Volume
- 12
- Issue
- 3
- Pages
- 277-282
- ISSN
- 1077-4114 (ISSN-L)
- OpenAlex
- W1970546425
- Cited by
- 75
- References
- 0
- FWCI
- 0.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cerebral Vessel Stenosis in Sickle Cell Disease: Criteria for Detection by Transcranial Doppler. https://app.cochat.ai/papers/10.1097/00043426-199023000-00005
- The paper
- Adams, R. J., Nichols, F. T., Aaslid, R., MCKie, V. C., MCKie, K., Carl, E., Stephens, S., Thompson, W. O., Milner, P., & Figueroa, R. (1990). Cerebral Vessel Stenosis in Sickle Cell Disease: Criteria for Detection by Transcranial Doppler. Journal of Pediatric Hematology/Oncology. https://doi.org/10.1097/00043426-199023000-00005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.