Building-Associated Pulmonary Disease From Exposure toStachybotrys chartarum and Aspergillus versicolor
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
The authors present an outbreak of disease associated with exposure to Stachybotrys chartarum and Aspergillus species. A courthouse and two associated office buildings had generated discomfort among employees for two years since initial occupancy. Multiple interventions had been unsuccessful An initial evaluation of 14 individuals identified three with potential asthma and three with symptoms consistent with interstitial lung disease. A clinical screening protocol to identify individuals who should be removed from work identified three likely and seven possible cases of building-related asthma. Detailed environmental and engineering assessments of the building identified major problems in mechanical system design, building construction, and operational strategies leading to excess moisture and elevated relative humidities. Moisture-damaged interior surfaces in both buildings were contaminated with S. chartarum, A. versicolor, and Penicillium species. Aspergillus species, especially A. versicolor, at concentrations of 10(1) to 10(4)/m3 dominated the indoor air under normal operating conditions. Bulk samples also revealed large quantities of Stachybotrys. A questionnaire survey of the three case and two control buildings documented between three- and 15-fold increases in symptoms. A nested case-control study suggested emphysematous-like disease in individuals meeting questionnaire definitions for cases. Replication of analysis strategies used in similar previous investigations suggested an association between worsening symptoms and decreased diffusing capacity of the lung. Performance on neuropsychological measures was similar for both cases and controls, although workers with symptoms reported increased levels of current but not past psychiatric symptomatology. Chemical analyses demonstrated the presence of satratoxins G and H. Cytotoxic laboratory analyses demonstrated the presence of agents with biological effectiveness in bulk materials. No association was seen between IgE or IgG antibodies and the presence of disease. This outbreak represents a likely human response to inhaled fungal toxins in indoor environments. Moisture indoors represents a public health issue currently inadequately addressed by building, health, or housing codes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standardization of Spirometry—1987 Update
(1987) · American Review of Respiratory Disease · doi:10.1164/ajrccm/136.5.1285 · Cited by 2,315
Fungi and mycotoxins in grain: Implications for stored product research
Miller, J. D. (1995) · Journal of Stored Products Research · doi:10.1016/0022-474x(94)00039-v · Cited by 434
SICK BUILDING SYNDROME: A STUDY OF 4373 OFFICE WORKERS
(1987) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/31.4a.493 · Cited by 416
Respiratory Health Effects of Home Dampness and Molds among Canadian Children
Dales, R. E., Zwanenburg, H., Burnett, R., & Franklin, C. A. (1991) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a116072 · Cited by 388
Airborne outbreak of trichothecene toxicosis
Croft, W. A., Jarvis, B. B., & Yatawara, C. S. (1986) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(86)90096-x · Cited by 345
Self-citationNon-Specific Symptoms In Office Workers: A Review And Summary Of The Epidemiologic Literature
Mendell, M. J. (1993) · Indoor Air · doi:10.1111/j.1600-0668.1993.00003.x · Cited by 284
Johanning, E., Biagini, R., Hull, D., Morey, P., Jarvis, B., & Landsbergis, P. (1996) · International Archives of Occupational and Environmental Health · doi:10.1007/bf00381430 · Cited by 277
Self-citationMycotoxins; production, isolation, separation and purification
Betina, V. (1984) · Developments in food science · Cited by 276
Strachan, D. P., & Sanders, C. H. (1989) · Journal of Epidemiology and Community Health · doi:10.1136/jech.43.1.7 · Cited by 158
Damp housing and adult respiratory symptoms
Brunekreef, B. (1992) · Allergy · doi:10.1111/j.1398-9995.1992.tb00672.x · Cited by 152
Cited by
Profiles of Airborne Fungi in Buildings and Outdoor Environments in the United States
Shelton, B. G., Kirkland, K. H., Flanders, W. D., & Morris, G. K. (2002) · Applied and Environmental Microbiology · doi:10.1128/aem.68.4.1743-1753.2002 · Cited by 673
The health effects of nonindustrial indoor air pollution
Bernstein, J. A., Alexis, N., Bacchus, H., Bernstein, I. L., Fritz, P., Horner, E., Li, N., Mason, S., Nel, A., Oullette, J., et al. (2008) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2007.10.045 · Cited by 574
Fungal volatile organic compounds: A review with emphasis on their biotechnological potential
Morath, S. U., Hung, R., & Bennett, J. W. (2012) · Fungal Biology Reviews · doi:10.1016/j.fbr.2012.07.001 · Cited by 523
(2005) · Choice Reviews Online · doi:10.5860/choice.42-4060 · Cited by 372
Mycotoxin production by indoor molds
Fog Nielsen, K. (2003) · Fungal Genetics and Biology · doi:10.1016/s1087-1845(03)00026-4 · Cited by 353
Indoor Mold, Toxigenic Fungi, and Stachybotrys chartarum: Infectious Disease Perspective
Kuhn, D. M., & Ghannoum, M. A. (2003) · Clinical Microbiology Reviews · doi:10.1128/cmr.16.1.144-172.2003 · Cited by 352
Bornehag, C. G., Sundell, J., Bonini, S., Custovic, A., Malmberg, P., Skerfving, S., Sigsgaard, T., & Verhoeff, A. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00240.x · Cited by 313
Acute Pulmonary Hemorrhage in Infants Associated With Exposure to Stachybotrys atra and Other Fungi
Etzel, R. A., Montaña, E., Sorenson, W. G., Kullman, G. J., Allan, T. M., & Dearborn, D. G. (1998) · Archives of Pediatrics & Adolescent Medicine · doi:10.1001/archpedi.152.8.757 · Cited by 295
Health Effects of Mycotoxins: A Toxicological Overview
Fung, F., & Clark, R. F. (2004) · Journal of Toxicology: Clinical Toxicology · doi:10.1081/clt-120030947 · Cited by 272
Idiopathic pulmonary haemosiderosis revisited
Ioachimescu, O. C., Sieber, S., & Kotch, A. (2004) · European Respiratory Journal · doi:10.1183/09031936.04.00116302 · Cited by 255
Mycotoxins in Crude Building Materials from Water-Damaged Buildings
Tuomi, T., Reijula, K., Johnsson, T., Hemminki, K., Hintikka, E.-L., Lindroos, O., Kalso, S., Koukila-Kähkölä, P., Mussalo-Rauhamaa, H., & Haahtela, T. (2000) · Applied and Environmental Microbiology · doi:10.1128/aem.66.5.1899-1904.2000 · Cited by 237
“chartarum (1, 24, 27) but as high as those found in building materials artificially inoculated with S.”
BackgroundAdverse Human Health Effects Associated with Molds in the Indoor Environment
&NA; (2003) · Journal of Occupational and Environmental Medicine · doi:10.1097/00043764-200305000-00006 · Cited by 237
Health Effects of Mycotoxins in Indoor Air: A Critical Review
Robbins, C. A., Swenson, L. J., Nealley, M. L., Kelman, B. J., & Gots, R. E. (2000) · Applied Occupational and Environmental Hygiene · doi:10.1080/10473220050129419 · Cited by 197
Production of mycotoxins on artificially and naturally infested building materials
Nielsen, K. F., Gravesen, S., Nielsen, P. A., Andersen, B., Thrane, U., & Frisvad, J. C. (1999) · Mycopathologia · doi:10.1023/a:1007038211176 · Cited by 195
“This study, and several others [6, 12, 23, 37, 39, 46 ], show that many of the fungal contaminants encountered in water-damaged buildings actually produce mycotoxins during growth on building materials.”
ResultHealth Effects of Indoor Fungal Bioaerosol Exposure
Fung, F., & Hughson, W. G. (2003) · Applied Occupational and Environmental Hygiene · doi:10.1080/10473220301451 · Cited by 181
Jaakkola, M. S., Nordman, H., Piipari, R., Uitti, J., Laitinen, J., Karjalainen, A., Hahtola, P., & Jaakkola, J. J. K. (2002) · Environmental Health Perspectives · doi:10.1289/ehp.02110543 · Cited by 179
“9 for occasional wheezing in association with mold exposure in problem office buildings in Florida (22).”
BackgroundInfluentialPestka, J. J., Yike, I., Dearborn, D. G., Ward, M. D. W., & Harkema, J. R. (2008) · Toxicological Sciences · doi:10.1093/toxsci/kfm284 · Cited by 178
“…of Stachybotrys-contaminated buildings failed to find a significant difference between the presence of IgE or IgG antibodies to this fungus in case and control individuals (Johanning et al., 1996) or a relationship of these antibodies to the presence of human disease (Hodgson et al., 1998).”
BackgroundMechanisms of Mycotoxin-Induced Neurotoxicity through Oxidative Stress-Associated Pathways
Doi, K., & Uetsuka, K. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12085213 · Cited by 174
“chartarum and its products or components have been postulated to etiologically contribute to damp building-related illnesses (DBRI) such as debilitating respiratory [58,59] and nonrespiratory symptoms involving immune and neurological impairment [56,60–62].”
Background
Metadata
- Authors
- Hodgson, M. J., Morey, P., Leung, W.-Y., Morrow, L., Miller, D., Jarvis, B. B., Robbins, H., Halsey, J. F., & Storey, E.
- Venue
- Journal of Occupational & Environmental Medicine
- Published
- 1998-03
- Volume
- 40
- Issue
- 3
- Pages
- 241-249
- ISSN
- 1076-2752 (ISSN-L)
- OpenAlex
- W2017663018
- Cited by
- 230
- References
- 20
- FWCI
- 8.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.